Revised HPLC Determination of Atenolol in Plasma and Urine

Abstract
An HPLC method for analysis of atenolol in human plasma and urine is presented. Based on alkaline extraction, acid backextraction and reverse phase ion-pair chromatography this method is quite specific for atenolol. For a 0.5 ml plasma sample the sensitivity ranges from 20 ng/ml in fasted healthy volunteers to 50 ng/ml in various groups of patients. A sensitivity in urine of 1.0 mcg/ml was sufficient for all samples studied. As presented this method has been used in several clinical pharmacokinetic studies involving hundreds of samples.