Revised HPLC Determination of Atenolol in Plasma and Urine
- 1 January 1983
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 16 (12), 941-949
- https://doi.org/10.1080/00032718308065231
Abstract
An HPLC method for analysis of atenolol in human plasma and urine is presented. Based on alkaline extraction, acid backextraction and reverse phase ion-pair chromatography this method is quite specific for atenolol. For a 0.5 ml plasma sample the sensitivity ranges from 20 ng/ml in fasted healthy volunteers to 50 ng/ml in various groups of patients. A sensitivity in urine of 1.0 mcg/ml was sufficient for all samples studied. As presented this method has been used in several clinical pharmacokinetic studies involving hundreds of samples.Keywords
This publication has 1 reference indexed in Scilit:
- Rapid Determination of Atenolol in Human Plasma and Urine by High-Pressure Liquid ChromatographyJournal of Pharmaceutical Sciences, 1978