A method using column switching and reversed-phase high performance liquid chromatography with diode array detection was developed for the screening of 16 diuretics, probenecid and caffeine in urine. First, a 40-μl sample is injected into a short ODS or ODP extraction column with water as eluent and polar matrix components are eluted to waste. The retained compounds are then eluted in backflush mode into the analytical column by means of a column switching valve and a gradient of 0.05 M phosphate buffer (pH 3.1) and acetonitrile. Wavelengths 230, 270 and 360 nm are used for the detection. Recoveries for spiked urine samples were near 100% and relative retention times showed good repeatability. Detection limits were 0.5–2.0 μg/ml.Keywords
This publication has 12 references indexed in Scilit:
- High-performance liquid chromatographic determination of diuretics in urine by micellar liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1992
- Analysis of diuretic doping agents by HPLC screening and GC—MSD confirmationJournal of Pharmaceutical and Biomedical Analysis, 1991
- Solid-Phase Extraction Techniques for Assay of Diuretics in Human Urine SamplesJournal of Liquid Chromatography, 1991
- Direct Injection Analysis of Diuretic and Anti-Inflammatory Drugs on a Shielded Hydrophobic Phase ColumnJournal of Liquid Chromatography, 1990
- Drug Testing at the 10th Asian Games and 24th Seoul Olympic GamesJournal of Analytical Toxicology, 1990
- Comprehensive screening procedure for diuretics in urine by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1989
- Determination of drug substances in biological fluids by direct injection multidimensional liquid chromatography with a micellar cleanup and reversed-phase chromatographyAnalytical Chemistry, 1988
- Determination of chlorthalidone in human plasma by reversed-phase micellar liquid chromatographyThe Analyst, 1988
- Liquid chromotographic screening of diuretics in urineJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- Drug level monitoring: cardiovascular drugsJournal of Chromatography B: Biomedical Sciences and Applications, 1985