Abstract
Cumulative dose distributions in fractionated radiation therapy depict the dose to normal tissues and therefore may permit an estimation of the risk of normal tissue complications. However, calculation of these distributions is highly challenging because of interfractional changes in the geometry of patient anatomy. This work presents an algorithm for deformable structure registration of the bladder and the verification of the accuracy of the algorithm using phantom and patient data. In this algorithm, the registration process involves conformal mapping of genus zero surfaces using finite element analysis, and guided by three control landmarks. The registration produces a correspondence between fractions of the triangular meshes used to describe the bladder surface. For validation of the algorithm, two types of balloons were inflated gradually to three times their original size, and several computerized tomography (CT) scans were taken during the process. The registration algorithm yielded a local accuracy of 4 mm along the balloon surface. The algorithm was then applied to CT data of patients receiving fractionated high-dose-rate brachytherapy to the vaginal cuff, with the vaginal cylinder in situ. The patients' bladder filling status was intentionally different for each fraction. The three required control landmark points were identified for the bladder based on anatomy. Out of an Institutional Review Board (IRB) approved study of 20 patients, 3 had radiographically identifiable points near the bladder surface that were used for verification of the accuracy of the registration. The verification point as seen in each fraction was compared with its predicted location based on affine as well as deformable registration. Despite the variation in bladder shape and volume, the deformable registration was accurate to 5 mm, consistently outperforming the affine registration. We conclude that the structure registration algorithm presented works with reasonable accuracy and provides a means of calculating cumulative dose distributions.Keywords
This publication has 17 references indexed in Scilit:
- Accuracy of finite element model‐based multi‐organ deformable image registrationMedical Physics, 2005
- Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Mapping of the prostate in endorectal coil‐based MRI/MRSI and CT: A deformable registration and validation studyMedical Physics, 2004
- Deformable image registration for the use of magnetic resonance spectroscopy in prostate treatment planningInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Zen and the art of medical image registration: correspondence, homology, and qualityNeuroImage, 2003
- Mutual-information-based registration of medical images: a surveyIEEE Transactions on Medical Imaging, 2003
- Evaluation of three‐dimensional finite element‐based deformable registration of pre‐ and intraoperative prostate imagingMedical Physics, 2001
- Image-based dose planning of intracavitary brachytherapy: registration of serial-imaging studies using deformable anatomic templatesInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical modelIEEE Transactions on Medical Imaging, 2001
- Principal warps: thin-plate splines and the decomposition of deformationsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1989