The Role of ECG-Gated MDCT in the Evaluation of Aortic and Mitral Mechanical Valves: Initial Experience
- 1 July 2008
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 191 (1), 26-31
- https://doi.org/10.2214/ajr.07.2951
Abstract
OBJECTIVE. The objective of our study was to evaluate the role of ECG-gated MDCT in the functional evaluation of mechanical prosthetic aortic and mitral valves.MATERIALS AND METHODS. Twenty sequential patients with 23 mechanical prosthetic valves were evaluated with an ECG-gated 40- or 64-MDCT scanner. Multiplanar reformation, maximal-intensity-projection, volume-rendering, and volume-averaging techniques were used for visualization of valve leaflets in systole and diastole. The visibility of each mechanical valve was evaluated by consensus of a radiologist and a cardiologist using a subjective 5-point scale (0–4). MDCT findings were correlated with fluoroscopic opening and closing angle measurements and echocardiographic pressure gradient measurements in 11 and 19 valves, respectively.RESULTS. The series included 18 bileaflet and five single-leaflet mechanical valves. The visibility score for the bileaflet mechanical valves was excellent (score of 4) in all 18 cases, but it was lower for single-leaflet v...Keywords
This publication has 11 references indexed in Scilit:
- Leaflet Movement of the ATS Valve in the Aortic Position: Unique Behavior Observed in 19-mm ValvesThe Annals of Thoracic Surgery, 2006
- Are all echocardiographic findings equally predictive for diagnosis in prosthetic endocarditis?Journal of the American Society of Echocardiography, 2004
- Usefulness of a multidetector-row computed tomography scanner for detecting pannus formationThe Annals of Thoracic Surgery, 2004
- Prosthetic Mitral Valve Thrombosis: Can Fluoroscopy Predict the Efficacy of Thrombolytic Treatment?Circulation, 2003
- Obstruction of st jude medical valves in the aortic position: histology and immunohistochemistry of pannusThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Obstruction of St Jude Medical valves in the aortic positionThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Incorrect echocardiographic diagnosis in patients with mechanical prosthetic valve dysfunction: correlation with surgical findingsAmerican Journal Of Medicine, 2000
- Reoperations for acute prosthetic thrombosis and pannus: an assessment of rates, relationship and riskEuropean Journal of Cardio-Thoracic Surgery, 1999
- Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parametersJournal of the American College of Cardiology, 1998
- Assessment of the opening angle of implanted Björk-Shiley prosthetic valves.Circulation, 1983