Skeletal dosimetry in the MAX06 and the FAX06 phantoms for external exposure to photons based on vertebral 3D-microCT images
- 20 November 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (24), 6265-6289
- https://doi.org/10.1088/0031-9155/51/24/001
Abstract
3D-microCT images of vertebral bodies from three different individuals have been segmented into trabecular bone, bone marrow and bone surface cells (BSC), and then introduced into the spongiosa voxels of the MAX06 and the FAX06 phantoms, in order to calculate the equivalent dose to the red bone marrow (RBM) and the BSC in the marrow cavities of trabecular bone with the EGSnrc Monte Carlo code from whole-body exposure to external photon radiation. The MAX06 and the FAX06 phantoms consist of about 150 million 1.2 mm cubic voxels each, a part of which are spongiosa voxels surrounded by cortical bone. In order to use the segmented 3D-microCT images for skeletal dosimetry, spongiosa voxels in the MAX06 and the FAX06 phantom were replaced at runtime by so-called micro matrices representing segmented trabecular bone, marrow and BSC in 17.65, 30 and 60 microm cubic voxels. The 3D-microCT image-based RBM and BSC equivalent doses for external exposure to photons presented here for the first time for complete human skeletons are in agreement with the results calculated with the three correction factor method and the fluence-to-dose response functions for the same phantoms taking into account the conceptual differences between the different methods. Additionally the microCT image-based results have been compared with corresponding data from earlier studies for other human phantoms.Keywords
This publication has 33 references indexed in Scilit:
- An improved MCNP version of the NORMAN voxel phantom for dosimetry studiesPhysics in Medicine & Biology, 2005
- All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetryPhysics in Medicine & Biology, 2004
- Mehrschicht-CT zur Strukturanalyse des trabekulären Knochens - Vergleich mit Mikro-CT und biomechanischer FestigkeitRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetryPhysics in Medicine & Biology, 2003
- CONVERSION COEFFICIENTS BASED ON THE VIP-MAN ANATOMICAL MODEL AND EGS4-VLSI CODE FOR EXTERNAL MONOENERGETIC PHOTONS FROM 10 keV TO 10 MeVHealth Physics, 2001
- Beta‐particle dosimetry of the trabecular skeleton using Monte Carlo transport within 3D digital imagesMedical Physics, 2001
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- Electron Absorbed Fractions and Dose Conversion Factors for Marrow and Bone by Skeletal RegionsHealth Physics, 2000
- Photoelectron Enhancement of the Absorbed Dose from X Rays to Human Bone Marrow: Experimental and Theoretical StudiesThe British Journal of Radiology, 1985
- Measurements of trabecular bone structure in man (for radionuclide dosimetryPhysics in Medicine & Biology, 1976