Covered Stents for Prevention of Restenosis
- 1 April 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 31 (4), 223-229
- https://doi.org/10.1097/00004424-199604000-00007
Abstract
Metallic stents in small vessels go along with a significant risk of restenosis and reocclusion. Different models of stents and covering materials have been purported to prevent intraluminal neointimal proliferation by cover-based closure of the spaces in the wire mesh. Tantalum stents covered with polyethylacrylate/polymethylmethacrylate (PEM) were implanted in the infrarenal aorta of six New Zealand white rabbits by aortotomy and compared with eight rabbits treated with uncovered tantalum stents. For deployment, covered and uncovered stents necessitated a 7-French (F) and 5-F sheath, respectively. In addition, nine human patients with arteriosclerotic lesions of the superficial femoral arteries (stenosis > 5 cm or total occlusion) were treated percutaneously with a Dacron-covered nitinol vascular stent via a 9-F sheath. Patients were followed for a mean of 13.5 months, and control angiography was performed after 6 months. Experimental placement of the tantalum Wiktor stent was feasible technically in all cases. Five of six stents covered with PEM were occluded 3 days after placement despite the intravenous use of heparin and aspirin. In the group with uncovered stents, no area of stenosis greater than 10% was observed. There was a neointimal layer of 89 +/- 68 microns around the stent wires. Stent placement was successful in all patients. In four patients, a hyperergic reaction occurred, resulting in noninfectious periarteriitis. This complication was treated successfully with nonsteroidal antiinflammatory drugs. The primary patency was 50%, and the secondary patency (after application of a second covered stent in two patients) was 63%. The uncovered stent induces little neointimal proliferation around the stent wires. The insertion of stents covered with PEM into the rabbit aorta was accompanied by a strong thrombotic reaction, despite sufficient anticoagulation. Dacron-covered nitinol stents showed a surprisingly high restenosis rate after 9 months of follow-up. Further research concerning the in vivo properties of new covering materials is mandatory before routine vascular clinical application.Keywords
This publication has 17 references indexed in Scilit:
- Prolonged proliferative response of smooth muscle cells after experimental intravascular stentingEuropean Heart Journal, 1995
- Guidelines for Development and Use of Transluminally Placed Endovascular Prosthetic Grafts in the Arterial SystemJournal of Vascular and Interventional Radiology, 1995
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- Percutaneous femoropopliteal graft placement.Radiology, 1993
- Intravascular stents: tissue-stent interactions and design considerations.American Journal of Roentgenology, 1993
- In Vitro and Clinical Feasibility Study with an Over-the-Wire Delivery System for Pulsed Dye Laser AngioplastyJournal of Vascular and Interventional Radiology, 1992
- Standards for Evaluating and Reporting the Results of Surgical and Percutaneous Therapy for Peripheral Arterial DiseaseJournal of Vascular and Interventional Radiology, 1991
- Treatment of iliac artery stenoses with the Wallstent endoprosthesis.American Journal of Roentgenology, 1990
- Percutaneous arterial grafting.Radiology, 1984
- Transluminal expandable nitinol coil stent grafting: preliminary report.Radiology, 1983