Nonstaphylococcal Infections of Cardiac Implantable Electronic Devices
- 18 May 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 121 (19), 2085-2091
- https://doi.org/10.1161/circulationaha.110.936708
Abstract
Background— Along with the rising use of cardiac implantable electronic devices (CIEDs), there has been a disproportional increase in the number of infections of such devices. Little is known about nonstaphylococcal CIED-related infections, which make up ≈10% to 30% of all CIED infections. Methods and Results— A retrospective review of hospital records of patients admitted with a CIED-related infection was conducted in 4 academic hospitals in Houston, Tex, between 2002 and 2009. Of the 504 identified patients with CIED-related infection, 80 (16%) had a nonstaphylococcal infection and were the focus of this study. The mean duration of CIED placement before infection was 109±27 weeks, whereas 44% had their device previously manipulated within a mean of 29.5±6 weeks. The mean duration of clinical symptoms before admission was 48±12.8 days. Furthermore, 13 patients (16%) presented with CIED-related endocarditis. Although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteria seeding of the CIED. Inappropriate antimicrobial coverage was provided in ≈50% of the cases with a mean period of 2.1 days. The overall mortality rate was 4%. Conclusions— Nonstaphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Because nonstaphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. In patients with suspected CIED infection, adequate Gram-positive and Gram-negative antibacterial coverage should be administered until microbiological data become available.Keywords
This publication has 14 references indexed in Scilit:
- Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative InsightsPacing and Clinical Electrophysiology, 2010
- Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator InfectionsJournal of the American College of Cardiology, 2007
- Frequency of Permanent Pacemaker or Implantable Cardioverter-Defibrillator Infection in Patients with Gram-Negative BacteremiaClinical Infectious Diseases, 2006
- Manifestations of familial hypercholesterolaemiaInternal Medicine Journal, 2005
- The additional hospital costs generated in the management of complications of pacemaker and defibrillator implantationsThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Evaluation of new clinical criteria for the diagnosis of infective endocarditisAmerican Journal Of Medicine, 1994
- Sustained Bacteremia in 26 Patients with a Permanent Endocardial Pacemaker: Assessment of Wire RemovalClinical Infectious Diseases, 1993
- Definitions for Sepsis and Organ Failure and Guidelines for the Use of Innovative Therapies in SepsisChest, 1992
- Extraction of implanted transvenous pacing leads: A review of a persistent clinical problemAmerican Heart Journal, 1991
- Infective Endocarditis: An Analysis Based on Strict Case DefinitionsAnnals of Internal Medicine, 1981