A Universal Denoising and Peak Picking Algorithm for LC−MS Based on Matched Filtration in the Chromatographic Time Domain
- 21 October 2003
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (22), 6314-6326
- https://doi.org/10.1021/ac0301806
Abstract
A new denoising and peak picking algorithm (MEND, matched filtration with experimental noise determination) for analysis of LC-MS data is described. The algorithm minimizes both random and chemical noise in order to determine MS peaks corresponding to sample components. Noise characteristics in the data set are experimentally determined and used for efficient denoising. MEND is shown to enable low-intensity peaks to be detected, thus providing additional useful information for sample analysis. The process of denoising, performed in the chromatographic time domain, does not distort peak shapes in the m/z domain, allowing accurate determination of MS peak centroids, including low-intensity peaks. MEND has been applied to denoising of LC-MALDI-TOF-MS and LC-ESI-TOF-MS data for tryptic digests of protein mixtures. MEND is shown to suppress chemical and random noise and baseline fluctuations, as well as filter out false peaks originating from the matrix (MALDI) or mobile phase (ESI). In addition, MEND is shown to be effective for protein expression analysis by allowing selection of a large number of differentially expressed ICAT pairs, due to increased signal-to-noise ratio and mass accuracy.Keywords
This publication has 14 references indexed in Scilit:
- Off-Line Coupling of High-Resolution Capillary Electrophoresis to MALDI-TOF and TOF/TOF MSJournal of Proteome Research, 2002
- Matched filtering with background suppression for improved quality of base peak chromatograms and mass spectra in liquid chromatography–mass spectrometryAnalytica Chimica Acta, 2001
- Isotopic Deconvolution of Matrix-Assisted Laser Desorption/Ionization Mass Spectra for Substance-Class Specific Analysis of Complex SamplesEuropean Journal of Mass Spectrometry, 2001
- Windowed mass selection method: a new data processing algorithm for liquid chromatography–mass spectrometry dataJournal of Chromatography A, 1999
- Application of sequential paired covariance to liquid chromatography-mass spectrometry data enhancements in both the signal-to-noise ratio and the resolution of analyte peaks in the chromatogramJournal of Chromatography A, 1997
- A Noise and Background Reduction Method for Component Detection in Liquid Chromatography/Mass SpectrometryAnalytical Chemistry, 1996
- Accuracy Requirements for Peptide Characterization by Monoisotopic Molecular Mass MeasurementsAnalytical Chemistry, 1996
- Application of Sequential Paired Covariance to Capillary Electrophoresis Electrospray Ionization Time-of-Flight Mass Spectrometry: Unraveling the Signal from the Noise in the ElectropherogramAnalytical Chemistry, 1995
- Optimal estimation of intensity of noisy peaks by matched filtering with application to chromatographyAnalytica Chimica Acta, 1990
- A general approach to calculating isotopic distributions for mass spectrometryInternational Journal of Mass Spectrometry and Ion Physics, 1983