Abstract
A prospective, randomized, blinded clinical trial was done to evaluate polyethylene versus metal bearing surfaces in total hip replacement. Forty-one patients were randomized to receive either a metal (23 patients) or a polyethylene (18 patients) insert. The femoral and acetabular components were identical with the acetabular insert the only variable. Patients were assessed preoperatively and postoperatively using radiographs, multiple outcome measures (Western Ontario MacMaster University Score, Harris hip score, Short Form-12), erythrocyte metal ion analysis (cobalt, chromium, titanium), and urine metal ion analysis (cobalt, chromium, titanium). Patients were followed up for a minimum of 2 years (mean 3.2 years; range, 2.2–3.9 years). There were no differences in radiographic outcomes or outcome measurement tools between patients. Patients receiving a metal-on-metal articulation had significantly elevated erythrocyte and urine metal ions compared with patients receiving a polyethylene insert. Patients who had metal-on-metal inserts had on average a 7.9-fold increase in erythrocyte cobalt, a 2.3-fold increase in erythrocyte chromium, a 1.7-fold increase in erythrocyte titanium, a 35.1-fold increase in urine cobalt, a 17.4-fold increase in urine chromium, and a 2.6-fold increase in urine titanium at 2 years followup. Patients receiving a polyethylene insert had no change in erythrocyte titanium, urine cobalt, or urine chromium and a 1.5-fold increase in erythrocyte cobalt, a 2.2-fold increase in erythrocyte chromium, and a 4.2-fold increase in urine titanium. Forty-one percent of patients receiving metal-on-metal articulations had increasing metal ion levels at the latest followup.Keywords
This publication has 33 references indexed in Scilit:
- Psychometric evaluation of the 12-item short-form health survey (SF-12) in osteoarthritis and rheumatoid arthritis clinical trialsClinical Therapeutics, 2001
- ELEVATED SERUM COBALT WITH METAL-ON-METAL ARTICULATING SURFACESThe Journal of Bone and Joint Surgery. British volume, 1997
- Biologic Effects of Cobalt Chrome in Cell and Animal ModelsClinical Orthopaedics and Related Research, 1996
- Catastrophic failure of the polyethylene liner of uncemented acetabular componentsThe Journal of Bone and Joint Surgery. British volume, 1994
- Severe polyethylene wear in total hip arthroplastyThe Journal of Arthroplasty, 1994
- A preliminary evaluation of the dimensionality and clinical importance of pain and disability in osteoarthritis of the hip and kneeClinical Rheumatology, 1986
- Chromium concentrations in serum, blood clot and urine from patients following total hip arthroplastyBiomaterials, 1985
- Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month studyBiomaterials, 1983
- Concentration of Wear Products in Hair, Blood, and Urine after Total Hip ReplacementBMJ, 1973
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969