Automated quantitative coronary arteriography: morphologic and physiologic validation in vivo of a rapid digital angiographic method.
- 1 February 1987
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 75 (2), 452-460
- https://doi.org/10.1161/01.cir.75.2.452
Abstract
Quantitative coronary arteriography has been shown to be useful in assessing the extent of coronary disease, its functional significance, and its response to therapeutic interventions. Most current methods rely either on hand-drawn arterial contours or automatic edge-detection algorithms applied to 35 mm cineangiograms. To assess the performance in vivo of a new, fully automatic, rapid coronary quantitation program, dogs were instrumented with precision-drilled, plastic cylinders to create intraluminal stenoses in the left anterior descending and/or circumflex arteries, as well as with high-fidelity micromanometers and electromagnetic flow probes. Stenosis diameters ranged from 0.83 to 1.83 mm. Biplane, on-line, digital coronary angiograms and cineangiograms were recorded during standard selective coronary arteriography in the closed-chest preparation. The on-line digital images were analyzed in nonsubtracted and subtracted modes. Cineangiograms were digitized to allow coronary quantitation by the same computer program. There was an excellent correlation between known and measured minimal diameter stenoses (r = .87 to .98, SEE = 0.09 to 0.24 mm). Interobserver and intraobserver variability analysis showed high reproducibility (r = .90 to .97, SEE = 0.12 to 0.23 mm). The best results in both analyses were achieved by nonsubtracted digital imaging and the worst by cineradiography. Measures of percent diameter stenosis, percent area stenosis (geometric and videometric), and absolute minimal cross-sectional area (geometric and videometric) were all significantly correlated with independent measures of actual coronary flow reserve. This study provides direct anatomic and physiologic validation in vivo of a new and rapid coronary quantitation method suitable for analysis of both digital angiograms and cineangiograms.This publication has 25 references indexed in Scilit:
- Digital quantification eliminates intraobserver and interobserver variability in the evaluation of coronary artery stenosisThe American Journal of Cardiology, 1985
- Noise in stenosis measurement using digital subtraction angiographyMedical Physics, 1985
- Assessment of dimensions and image quality of coronary contrast catheters from cineangiogramsCatheterization and Cardiovascular Diagnosis, 1985
- Quantitative Digital FluorographyInvestigative Radiology, 1985
- Digital subtraction coronary angiography using high‐pass temporal filtration: A comparison with cineangiographyCatheterization and Cardiovascular Diagnosis, 1985
- Detection and quantitation of coronary artery stenoses from digital subtraction angiograms compared with 35-millimeter film cineangiogramsThe American Journal of Cardiology, 1984
- Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: Diameter versus densitometric area measurementsThe American Journal of Cardiology, 1984
- The value of lesion cross-sectional area determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending coronary arterial stenoses.Circulation, 1984
- Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms.Circulation, 1984
- Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devicesMedical Physics, 1981