Effect of static magnetic field exposure of up to 8 Tesla on sequential human vital sign measurements
Open Access
- 18 August 2003
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (3), 346-352
- https://doi.org/10.1002/jmri.10367
Abstract
Purpose To determine if increasing static magnetic field strength exposures up to 8 Tesla (T) affect vital signs or electrocardiograms (ECGs) in normal human volunteers. Materials and Methods We studied 25 normal subjects, consisting of 19 men and six women, ages 24–53 years. The vital signs and ECGs of the subjects were measured 14 times inside and outside the magnetic field. This included the heart rate, respiratory rate, systolic and diastolic blood pressures, finger pulse oxygenation levels, core body temperature via the external auditory canal temperature, and fiber optic core body sublingual temperatures. Inside the magnetic field the vital signs were measured sequentially at field strengths of 8, 6, 4.5, 3, and 1.5 T. Results The only statistically significant effect of magnetic field strength was observed with systolic blood pressure. An average increase of 3.6 mm Hg in systolic blood pressure was seen with 8 T exposure. ECG rhythm strip analysis demonstrated no significant changes post-exposure. Conclusions Normal subjects exposed to varying magnetic field strengths of up to 8 T demonstrated no clinically significant changes in vital signs. Transient ECG artifacts were noted to increase with the field strength. J. Magn. Reson. Imaging 2003;18:346–352.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of 1.5 and 8 Tesla High-Resolution Magnetic Resonance Imaging of Lacunar InfarctsJournal of Computer Assisted Tomography, 2002
- Radiofrequency Energy-Induced Heating During MR Procedures: A ReviewJournal of Magnetic Resonance Imaging, 2000
- Auditory Noise Associated With MR Procedures: A ReviewJournal of Magnetic Resonance Imaging, 2000
- Aneurysm Clips: Evaluation of Magnetic Field Interactions With an 8.0 T MR SystemJournal of Magnetic Resonance Imaging, 2000
- High Resolution MRI of the Deep Brain Vascular Anatomy at 8 Tesla: Susceptibility-Based Enhancement of the Venous StructuresJournal of Computer Assisted Tomography, 1999
- High Resolution MRI of the Deep Gray Nuclei at 8 TeslaJournal of Computer Assisted Tomography, 1999
- Safety considerations in MR imaging.Radiology, 1990
- Alterations in body and skin temperatures caused by magnetic resonance imaging: is the recommended exposure for radiofrequency radiation too conservative?The British Journal of Radiology, 1989
- Exposure to a 1.5‐T static magnetic field does not alter body and skin temperatures in manMagnetic Resonance in Medicine, 1989
- Temperature, heart rate, and blood pressure changes associated with clinical MR imaging at 1.5 T.Radiology, 1987