Automated In-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography/Electrospray Ionization Mass Spectrometry for the Determination of β-Blockers and Metabolites in Urine and Serum Samples
- 3 September 1999
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (19), 4237-4244
- https://doi.org/10.1021/ac990356x
Abstract
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. LC/MS analyses of beta-blockers were initially performed by liquid injection onto a LC column. Nine beta-blockers tested in this study gave very simple ESI mass spectra, and strong signals corresponding to [M + H]+ were observed for all beta-blockers. The beta-blockers were separated with a Hypersil BDS C18 column using acetonitrile/methanol/water/acetic acid (15:15:70:1) as a mobile phase. To optimize the extraction of beta-blockers, several in-tube SPME parameters were examined. The optimum extraction conditions were 15 draw/eject cycles of 30 microL of sample in 100 mM Tris-HCl (pH 8.5) at a flow rate of 100 microL/min using an Omegawax 250 capillary (Supelco, Bellefonte, PA). The beta-blockers extracted by the capillary were easily desorbed by mobile-phase flow, and carryover of beta-blockers was not observed. Using in-tube SPME/LC/ESI-MS with selected ion monitoring, the calibration curves of beta-blockers were linear in the range from 2 to 100 ng/mL with correlation coefficients above 0.9982 (n = 18) and detection limits (S/N = 3) of 0.1-1.2 ng/mL. This method was successfully applied to the analysis of biological samples without interference peaks. The recoveries of beta-blockers spiked into human urine and serum samples were above 84 and 71%, respectively. A serum sample from a patient administrated propranolol was analyzed using this method and both propranolol and its metabolites were detected.Keywords
This publication has 23 references indexed in Scilit:
- Solid Phase Microextraction (SPME)The Chemical Educator, 1997
- Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid ChromatographyAnalytical Chemistry, 1997
- New Trends in Solid-Phase MicroextractionCritical Reviews in Analytical Chemistry, 1997
- Performance of micellar mobile phases in reversed-phase chromatography for the analysis of pharmaceuticals containing β-blockers and other antihypertensive drugsThe Analyst, 1996
- Determination of nine β-blockers in serum by micellar electrokinetic capillary chromatographyJournal of Chromatography A, 1994
- Screening of β-blockers in human serum by ion-pair chromatography and their identification as methyl or acetyl derivatives by gas chromatography—mass spectrometryJournal of Chromatography A, 1993
- Determination of Some β‐Blockers as Dabsyl Derivatives by HPLCArchiv der Pharmazie, 1990
- High-performance liquid chromatographic determination of β-adrenoceptor blocking agents in body fluidsBiomedical Chromatography, 1989
- A strategy for the determination of beta blockers in plasma using solid-phase extraction in combination with high-performance liquid chromatographyJournal of Pharmaceutical and Biomedical Analysis, 1989
- Ring-hydroxylated propranolol: synthesis and .beta.-receptor antagonist and vasodilating activities of the seven isomersJournal of Medicinal Chemistry, 1981