Comparison of the effects of absorption coefficient and pulse duration of 2.12-μm and 2.79-μm radiation on laser ablation of tissue
- 1 December 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 32 (12), 2025-2036
- https://doi.org/10.1109/3.544746
Abstract
Erbium and holmium lasers are attractive for minimally invasive surgical applications as they operate at wavelengths where tissues exhibit strong absorption due to their water content and because these wavelengths are transmittable through optical fibers. In this study, the basic physical mechanisms underlying tissue ablation and the laser-induced tissue effects using pulsed Er:YSGG (2.79 /spl mu/m) and Ho:YAG (2.12 /spl mu/m) laser radiation are presented and compared, Q-switched (/spl tau/=40 ns, E/spl les/50 mJ) and free-running (/spl tau/=250 and 400 /spl mu/s) Er:YSGG (E=100 mJ) and Ho:YAG (E/spl les/1 J) laser energy was delivered in water via a 400-/spl mu/m fiber. The dimension and lifetime of the expanding and collapsing bubbles and the laser-induced pressure in water after each laser pulse were measured with fast-flash videography and time-resolved pressure measurements. Depending on the absorption coefficient, pulse energy, and pulse duration, three different regimes were distinguished: evaporation, tensile-stress-induced cavitation, and explosive vaporization. In vitro tissue effects, ablation depth, and extent of tissue damage on meniscus treated under water and on cornea treated in air were investigated and examined histologically. Er:YSGG radiation, due to its 100 times higher absorption than Ho:YAG radiation, exhibited a high tissue ablation efficiency with a relatively small zone of coagulated tissue (Q-switched 4-10 /spl mu/m, free-running less than 100 /spl mu/m), whereas the coagulated tissue zone was 300-1000 /spl mu/m after free-running and 100-120 /spl mu/m after Q-switched Ho:YAG laser impact.Keywords
This publication has 51 references indexed in Scilit:
- Temperature and pressure effects during erbium laser stapedotomyLasers in Surgery and Medicine, 1996
- Partial vaporization model for pulsed mid-infrared laser ablation of waterJournal of Applied Physics, 1995
- Dynamics of laser-induced channel formation in water and influence of pulse duration on the ablation of biotissue under water with pulsed erbium-laser radiationApplied Physics B Laser and Optics, 1994
- Fibre-end micro-lens system for endoscopic erbium-laser surgery applicationsApplied Physics B Laser and Optics, 1994
- Channel propagation in water and gelatin by a free-running erbium laserJournal of Applied Physics, 1993
- Potential use of holmium lasers for angioplasty: Evaluation of a new solid-state laser for ablation of atherosclerotic plaqueLasers in Surgery and Medicine, 1991
- Dielectric-coated metallic hollow waveguide for 3-μm Er:YAG, 5-μm CO, and 106-μm CO_2 laser light transmissionApplied Optics, 1990
- Er:YAG laser ablation of tissue: Measurement of ablation ratesLasers in Surgery and Medicine, 1989
- Laser ablation of atherosclerotic blood vessel tissue under various irradiation conditionsIEEE Transactions on Biomedical Engineering, 1989
- The Near Infrared Absorption Spectrum of Liquid WaterJournal of the Optical Society of America, 1951