Indirect measurement of blood pressure during exercise testing can be misleading.
Open Access
- 1 June 1985
- Vol. 53 (6), 611-615
- https://doi.org/10.1136/hrt.53.6.611
Abstract
Indirect blood pressures recorded with a random zero sphygmomanometer were compared with simultaneous intra-arterial blood pressures recorded with the Oxford system. Twenty five patients undertook a graded bicycle exercise test, cycling at workloads increasing from 41, 65, 114, and 163 W (250 to 400, 700, and 1000 kpm per min) with each grade being maintained for three minutes unless the exercise test was terminated earlier at the point of fatigue. Intra-arterial pressures were recorded continuously and indirect measurements made at steady state levels in the 30 seconds before each change in grade and immediately after the termination of the exercise protocol. The mean difference in systolic blood pressure at 5.5 minutes of exercise showed that the indirect measurement underestimated the direct measurement. Immediately after the termination of exercise the blood pressure fell precipitiously to a highly significant degree. For both systolic and diastolic pressures there was considerably individual variability. These data confirm that indirect methods of blood pressure measurement during dynamic exercise testing are inaccurate and may provide misleading information.This publication has 16 references indexed in Scilit:
- Measurement in Medicine: The Analysis of Method Comparison StudiesJournal of the Royal Statistical Society: Series D (The Statistician), 1983
- CONTINUOUS RECORDING OF INTRA-ARTERIAL BLOOD-PRESSURE DURING GRADED BICYCLE ERGOMETRY AND STAIR CLIMBING IN ESSENTIAL-HYPERTENSION1981
- Variations in and significance of systolic pressure during maximal exercise (treadmill) testing: Relation to severity of coronary artery disease and cardiac mortalityThe American Journal of Cardiology, 1977
- A RANDOM-ZERO SPHYGMOMANOMETERThe Lancet, 1970
- Impaired Maximal Exercise Performance with Hypertensive Cardiovascular DiseaseCirculation, 1969
- VARIATION OF BLOOD-PRESSURE IN UNTREATED HYPERTENSIVE OUTPATIENTSThe Lancet, 1969
- The Indirect Method of Recording Blood PressureCardiovascular Research, 1968
- Measurement of Blood-pressure: Comparison of Intra-arterial and Cuff ValuesBMJ, 1964
- Age Changes in Heart Rate and Blood Pressure Responses to Tilting and Standardized ExerciseCirculation, 1953
- THE NORMAL HUMAN BLOOD PRESSURE DURING AND AFTER EXERCISE, WITH SOME RELATED OBSERVATIONS ON CHANGES IN THE HEART RATE AND THE BLOOD FLOW IN THE LIMBSImmunology & Cell Biology, 1952