Biomechanical Analysis of Single Screw Fixation for Slipped Capital Femoral Epiphysis
- 1 July 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 26 (4), 474-478
- https://doi.org/10.1097/01.bpo.0000217732.24041.81
Abstract
To evaluate single screw fixation stability, in the treatment of slipped capital femoral epiphysis, as a function of screw thread distribution across the physis. In vitro biomechanical study. Thirty porcine proximal femurs were sectioned through the physeal line and stabilized with a cannulated 7.3-mm stainless steel AO screw. The distal 16 mm of each screw was threaded (5 threads). The femurs were randomized into 5 groups (1, 2, 3, 4, or 5 threads across the physis) and biomechanically tested to determine failure load (N) and stiffness (N/mm). Femurs with 2 or 3 threads across the physis had a significantly greater load to failure and stiffness compared with femurs with 1, 4, or 5 threads across the physis (P < 0.05). Thread distribution across the physis seems to be important. When using screws with a 16-mm thread, greatest strength and stiffness are achieved when 40%-60% of threads engage the epiphysis, with a significant decrease when greater than 80% of threads cross the physis. Too few threads in the epiphysis as well as too few in the metaphysis both lead to decreased stability. This study challenges the belief that compression across the physis maximizes slipped capital femoral epiphysis fixation stability. We recommend equal distribution of threads across the physis when using 16-mm thread screws, and we postulate that screws with a greater thread length (32 mm or fully threaded) would increase fixation stability even further. Optimizing purchase may decrease the incidence of slip progression, especially as the prevalence of obesity increases in the adolescent population.Keywords
This publication has 33 references indexed in Scilit:
- Slip Progression After In Situ Single Screw Fixation for Stable Slipped Capital Femoral EpiphysisJournal of Pediatric Orthopaedics, 2003
- Ultrasound in the diagnosis of fractures in childrenThe Journal of Bone and Joint Surgery, 2000
- Biomechanical Analysis of Single- Versus Double-Screw Fixation in Slipped Capital Femoral Epiphysis at Physiological Load LevelsJournal of Pediatric Orthopaedics, 1994
- Subtrochanteric Fracture After Fixation of Slipped Capital Femoral EpiphysisJournal of Pediatric Orthopaedics, 1994
- Single Versus Double Screw Fixation for Treatment of Slipped Capital Femoral EpiphysisJournal of Pediatric Orthopaedics, 1992
- Comparison of Single Pin Versus Multiple Pin Fixation in Treatment of Slipped Capital Femoral EpiphysisJournal of Pediatric Orthopaedics, 1992
- Biomechanical Comparison of Single- and Double-Pin Fixation for Acute Slipped Capital Femoral EpiphysisPublished by Wolters Kluwer Health ,1990
- Slipped capital femoral epiphysis in southern Sweden 1910-1982Acta Orthopaedica, 1987
- Slipped Capital Femoral Epiphysis: Factors Affecting Shear Forces on the Epiphyseal PlateJournal of Pediatric Orthopaedics, 1984
- Effects of Compression on Growth Plates in the RabbitActa Orthopaedica, 1983