Errors in Laboratory Medicine
Top Cited Papers
Open Access
- 1 May 2002
- journal article
- review article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 48 (5), 691-698
- https://doi.org/10.1093/clinchem/48.5.691
Abstract
Background: The problem of medical errors has recently received a great deal of attention, which will probably increase. In this minireview, we focus on this issue in the fields of laboratory medicine and blood transfusion. Methods: We conducted several MEDLINE queries and searched the literature by hand. Searches were limited to the last 8 years to identify results that were not biased by obsolete technology. In addition, data on the frequency and type of preanalytical errors in our institution were collected. Results: Our search revealed large heterogeneity in study designs and quality on this topic as well as relatively few available data and the lack of a shared definition of “laboratory error” (also referred to as “blunder”, “mistake”, “problem”, or “defect”). Despite these limitations, there was considerable concordance on the distribution of errors throughout the laboratory working process: most occurred in the pre- or postanalytical phases, whereas a minority (13–32% according to the studies) occurred in the analytical portion. The reported frequency of errors was related to how they were identified: when a careful process analysis was performed, substantially more errors were discovered than when studies relied on complaints or report of near accidents. Conclusions: The large heterogeneity of literature on laboratory errors together with the prevalence of evidence that most errors occur in the preanalytical phase suggest the implementation of a more rigorous methodology for error detection and classification and the adoption of proper technologies for error reduction. Clinical audits should be used as a tool to detect errors caused by organizational problems outside the laboratory.Keywords
This publication has 34 references indexed in Scilit:
- Large Differences in Laboratory Utilisation between Hospitals in Swedencclm, 2000
- Reference Intervals: Are Interlaboratory Differences Appropriate?cclm, 1999
- External Quality Assessment of Stat Test Intralaboratory Turnaround Times. Pilot Study from the Members of the Working Group for the Standardization and Promotion of Turnaround Time Control under the Auspices of the Comitato Italiano per la Standardizzazione die Metodi Ematologici e di Laboratoriocclm, 1998
- Promoting Patient Safety by Preventing Medical ErrorJAMA, 1998
- Do We Know What Inappropriate Laboratory Utilization Is?JAMA, 1998
- Are Physicians' Office Laboratory Results of Comparable Quality to Those Produced in Other Laboratory Settings?Published by American Medical Association (AMA) ,1998
- Problems in Laboratory Testing in Primary CarePublished by American Medical Association (AMA) ,1996
- Transfusion Errors: Causes and EffectsTransfusion Medicine Reviews, 1994
- Errors in blood transfusion in Britain: survey of hospital haematology departmentsBMJ, 1994
- Monitoring transfusionist practices: a strategy for improving transfusion safetyTransfusion, 1994