Abstract
A new simple and rapid ultrasound-assisted ionic liquid-based microextraction method was applied to preconcentrate aluminum(III), gallium(III), and indium(III) ions from water samples as a prior step to their simultaneous spectrophotometric determination using least squares support vector machines regression. In the novel procedure, 1-hexyl-3-methylimidazolium hexafluorophosphate [C6MIM][PF6] was dispersed into the aqueous sample solution as fine droplets by ultrasonication, and the analytes were extracted into the ionic liquid phase after complexation with 1,2,5,8-tetrahydroxy anthraquinone (quinalizarine). After centrifuging, the fine droplets of extractant phase were settled to the bottom of the conical-bottom glass centrifuge tube. The detection limits for Al(III), Ga(III), and In(III) were 1.70, 2.02, and 2.06 ng mL−1, respectively. The precision of the method, evaluated as the relative standard deviation obtained by analyzing a series of ten replicates, was below 3.2% for all elements. The method was successfully applied for the determination of Al(III), Ga(III), and In(III) in real samples.

This publication has 47 references indexed in Scilit: