Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography
- 16 July 2002
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 29 (8), 1643-1650
- https://doi.org/10.1118/1.1493213
Abstract
We investigated how varying the x-ray tube voltage and image receptor input exposure affected image quality and patient radiation doses in interventional neuroradiologic imaging. Digital subtraction angiography (DSA) images were obtained of a phantom with 1 mm diameter vessels containing iodine at concentrations between 4.5 and 50 mg/cc. The detection threshold concentration of iodine was determined by inspecting DSA images obtained at a range of x-ray tube voltages and input exposure levels. Surface doses were obtained from measured x-ray tube output data, and corresponding values of energy imparted were determined using the exposure-area product incident on the phantom. In one series of experiments, the air kerma at the image intensifier (X) was varied between 0.44 microGy per frame and 8.8 microGy per frame at a constant x-ray tube voltage of 70 kVp. In a second series of experiments, the tube voltage was varied between 50 and 100 kVp, and the mAs adjusted to maintain a constant exposure level at the input of the image intensifier. At a constant x-ray tube voltage, the surface dose and energy imparted were directly proportional to the input exposure per frame used to acquire the DSA images. On our DSA system operated below 2.2 microGy per frame, the threshold iodine concentration was found to be proportional to X(-0.57), which is in reasonable agreement with the theoretical prediction for a quantum noise limited imaging system. Above 2.2 microGy per frame, however, the threshold iodine concentration was proportional to X(-0.26), indicating that increasing the input exposure above this value will only achieve modest improvements in image quality. At a constant image intensifier input exposure level, increasing the x-ray tube voltage from 50 kVp to 100 kVp reduced the surface dose by a factor of 6.1, and the energy imparted by a factor of 3.5. The detection threshold iodine concentration was found to be proportional to kVp(n), where n was 2.1 at 1.1 microGy per frame, and 1.6 at 3.9 microGy per frame. For clinical situations that can be modeled by a uniform phantom, reducing the x-ray tube voltage rather than increasing the exposure level would best achieve improvements on our DSA imaging system performance.Keywords
This publication has 21 references indexed in Scilit:
- Effective dose and energy imparted in diagnostic radiologyMedical Physics, 1997
- Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculationsPhysics in Medicine & Biology, 1995
- Potential Biological Effects Following High X-ray Dose Interventional ProceduresJournal of Vascular and Interventional Radiology, 1994
- Comparison of performance characteristics of conventional and K-edge filters in general diagnostic radiologyPhysics in Medicine & Biology, 1989
- Basic imaging properties of a computed radiographic system with photostimulable phosphorsMedical Physics, 1989
- The influence of tube filtration and potential on patient dose during X-ray examinationsPhysics in Medicine & Biology, 1988
- Filter materials for dose reduction in screen-film radiographyPhysics in Medicine & Biology, 1986
- Investigation of basic imaging properties in digital radiography. 5. Characteristic curves of II-TV digital systemsMedical Physics, 1986
- Noise analysis of a digital radiography systemAmerican Journal of Roentgenology, 1984
- Photon mass attenuation and energy-absorption coefficientsThe International Journal of Applied Radiation and Isotopes, 1982