AMO array multifocal lens versus monofocal correction in cataract surgery
- 1 January 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 26 (1), 96-100
- https://doi.org/10.1016/s0886-3350(99)00335-1
Abstract
To compare the functional capabilities of 15 patients (30 eyes) who had implantation of the Allergan Medical Optics (AMO) Array™ multifocal intraocular lens (IOL) with those of 13 patients (26 eyes) with an AMO monofocal IOL. Department of Ophthalmology, The University of Western Ontario, Canada. The objective capabilities of both groups were analyzed through visual acuity measurements for distance, near, and depth of focus. Subjective functionality was assessed through the use of a questionnaire that included the previously validated VF-14 index of visual function, a global measure of overall satisfaction with visual acuity, and questions related to the frequency of spectacle wear. Both groups had excellent corrected and uncorrected distance visual acuity postoperatively. The multifocal group had better acuity than the monofocal group at near with distance correction in place (70% versus 43% achieved J3 or better). The multifocal group also had significantly better depth of focus. Subjectively, both groups indicated high levels of satisfaction with visual function. However, the multifocal group indicated higher levels of satisfaction during the day, at night, and overall without spectacles. This result translated into less spectacle wear for both near and distance in the multifocal group. The results of this study indicate high patient satisfaction with the Array multifocal IOL and greater functional independence from spectacle wear, by objective and subjective patient measures, than with the monofocal IOL.Keywords
This publication has 9 references indexed in Scilit:
- Outcomes of Cataract Extraction with Multifocal Intraocular Lens ImplantationOphthalmology, 1997
- Changes in pupil size induced by phacoemulsification and posterior chamber lens implantation: Consequences for multifocal lensesJournal of Cataract & Refractive Surgery, 1996
- Effect of age and astigmatism on the AMO Array multifocal intraocular lensJournal of Cataract & Refractive Surgery, 1995
- Contrast sensitivity, glare, and visual function: Diffractive multifocal versus bilateral monofocal intraocular lensesJournal of Cataract & Refractive Surgery, 1995
- National Study of Cataract Surgery OutcomesOphthalmology, 1994
- The VF-14Archives of Ophthalmology (1950), 1994
- Prospectively randomized trial comparing the pseudoaccommodation of the AMO ARRAY multifocal lens and a monofocal lensJournal of Cataract & Refractive Surgery, 1993
- A Prospective, Randomized, Double-masked Comparison of a Zonal-Progressive Multifocal Intraocular Lens and a Monofocal Intraocular LensOphthalmology, 1992
- Optical performance of multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 1990