Kinetic Sequential Sampling (KSS) System: An Automated Sampling System for Measuring Vertical Concentration Profiles of Airborne Particles
- 1 August 1998
- journal article
- research article
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 48 (8), 757-762
- https://doi.org/10.1080/10473289.1998.10463723
Abstract
An electronically controlled lift system carrying a realtime particle monitor has been developed for sampling air sequentially, at different heights within the breathing zone. Data are automatically logged at the different receptor levels, for the determination of average vertical concentration profiles of airborne particulate matter. The system is easy to operate, portable, and easily extended to different heights or modified for use with other types of monitors (e.g., a portable CO analyzer). For measuring airborne particle concentrations, a Grimm Dust Monitor 1.104/5 was used. The results of trial runs, which were carried out indoors and in a relatively open semi-rural area, are presented, and applications of the kinetic sequential sampling (KSS) system are discussed.Keywords
This publication has 3 references indexed in Scilit:
- Informed consent and manual therapyManual Therapy, 1996
- Physiologically based assessment of human exposure to urban air pollutants and its significance for public health risk evaluation.Environmental Health Perspectives, 1994
- Revising the Particulate Ambient Air Quality StandardEnvironmental Science & Technology, 1994