Direct comparison of 3D spiral vs. Cartesian gradient‐echo coronary magnetic resonance angiography
Open Access
- 2 October 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (4), 789-794
- https://doi.org/10.1002/mrm.1258
Abstract
While 3D thin‐slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k‐space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k‐space gradient‐echo and spiral k‐space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T2 preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R‐R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal‐to‐noise ratio (SNR) and contrast‐to‐noise‐ratio (CNR) (both P < 0.001) and image quality. The single spiral per R‐R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6‐fold increase in SNR. The double‐interleaf spiral approach showed a 50% reduction in scanning time, a 1.8‐fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be “traded” for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution. Magn Reson Med 46:789–794, 2001.Keywords
This publication has 25 references indexed in Scilit:
- Improved 3D spiral imaging for coronary MR angiographyMagnetic Resonance in Medicine, 2001
- A fast 3D approach for coronary MRAJournal of Magnetic Resonance Imaging, 1999
- Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiographyJournal of the American College of Cardiology, 1999
- Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRACirculation, 1999
- Fast magnetic resonance coronary angiography with a three-dimensional stack of spirals trajectoryMagnetic Resonance in Medicine, 1999
- Prospective adaptive navigator correction for breath‐hold MR coronary angiographyMagnetic Resonance in Medicine, 1997
- Coronary artery imaging at 0.5 t using segmented 3d echo planar imagingMagnetic Resonance in Medicine, 1995
- The diminishing variance algorithm for real‐time reduction of motion artifacts in MRIMagnetic Resonance in Medicine, 1995
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995
- Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast.Radiology, 1993