Measurement of the Glucose Transport Time Delay Between the Blood and Aqueous Humor of the Eye for the Eventual Development of a Noninvasive Glucose Sensor
- 1 June 2001
- journal article
- research article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 3 (2), 201-207
- https://doi.org/10.1089/152091501300209552
Abstract
In the recent past, several noninvasive optically based methods have been proposed for physiologic glucose sensing. One proposed optical sensing site has been the eye, which, due to its unique optical properties, can be considered as a transparent optical window into the body. In particular, the aqueous humor within the anterior chamber of the eye has been shown to contain glucose levels correlated to those of blood. Concern, however, has been expressed that using the aqueous humor solution as a measure of blood glucose may be problematic due to the potential transport time delay between the blood and the aqueous humor glucose concentrations. This investigation was performed to measure the transport time delay in a rabbit model. The time delay between the blood and aqueous humor glucose concentrations was measured invasively in five New Zealand White rabbits over a series of weeks. An anesthesia protocol containing the drug Xylazine was used to elevate the blood glucose levels to a level commonly seen in diabetic patients. The difference between the glucose peak location times occurring in the blood and aqueous humor glucose response was measured and defined as the transport time delay. The average transport time lag was measured to be under 5 min. This measured time delay indicates that, indeed, the eye could potentially be used as a sensing site for indirect blood glucose measurements and may eventually aid the development of a noninvasive glucose sensor due to its unique optical properties compared to other biological tissues.Keywords
This publication has 17 references indexed in Scilit:
- The Use of Polarized Laser Light Through the Eye for Noninvasive Glucose MonitoringDiabetes Technology & Therapeutics, 1999
- Noninvasive polarimetric measurement of glucose in cell culture mediaJournal of Biomedical Optics, 1997
- Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approachIEEE Transactions on Biomedical Engineering, 1997
- Application of a multivariate technique to Raman spectra for quantification of body chemicalsIEEE Transactions on Biomedical Engineering, 1995
- Analysis of metabolites in aqueous solutions by using laser Raman spectroscopyApplied Optics, 1993
- Can continuous glucose monitoring be used for the treatment of diabetes?Analytical Chemistry, 1992
- Increased Glucose Content in the Aqueous Humour Caused by the Use of XylazineOphthalmic Research, 1990
- Impact of blood glucose monitoring on diabetic control: Obstacles and interventionsJournal of Behavioral Medicine, 1989
- Alterations of Glucose Levels in the Blood and the Anterior Eye Segment of Rabbits Exposed to Ketamine-Xylazine AnaesthesiaOphthalmic Research, 1987
- Diabetic control and microvascular complications: The near-normoglycaemic experienceDiabetologia, 1986