Tissue standard ratios for irregularly shaped radiotherapy fields
- 8 August 1990
- journal article
- research article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 63 (752), 629-634
- https://doi.org/10.1259/0007-1285-63-752-629
Abstract
A method of calculating dose for a 6 MV X-ray beam using tissue standard ratios (TSR) is described. TSRs may be divided into a primary component and a scatter component, and the latter can then be further divided into contributions from elemental scattering volumes of 1 cm .times. 1 cm cross-sectional area at 1 m from the source. The magnitude of the various components have been determined by analysing measurements of square and rectangular fields, involving the fitting of the scatter data to an exponential function of radial distance from the scatter element. The coefficient and exponent of this function were found to be functions of depth, and this variation is described. A method of utilizing reconstructed scatter data that is compatible with the motion of a multileaf collimator system is presented. Results obtained by re-combining the data for various non-standard geometries are compared with further experimental work.This publication has 7 references indexed in Scilit:
- Comments on “Validity of the concept of separating primary and scatter dose”Medical Physics, 1986
- Validity of the concept of separating primary and scatter doseMedical Physics, 1985
- Program IRREG — Calculation of dose from irregularly shaped radiation beamsComputer Programs in Biomedicine, 1972
- Scatter-air ratiosPhysics in Medicine & Biology, 1972
- Central axis depth doses for a constant source-tumour distanceThe British Journal of Radiology, 1968
- The Production of Isodose Curves and the Calculation of Energy Absorption from Standard Depth Dose DataThe British Journal of Radiology, 1944
- A Note on Depth Doses in Fields of Irregular ShapeThe British Journal of Radiology, 1941