Effects of localised, low-voltage pulsed electric fields on the development and inhibition ofPseudomonas aeruginosabiofilms
- 1 January 2006
- journal article
- research article
- Published by Taylor & Francis in Biofouling
- Vol. 22 (6), 383-390
- https://doi.org/10.1080/08927010601053541
Abstract
This work describes the use of low-voltage (0.5 – 5 V) pulsed electric fields to prevent Pseudomonas aeruginosa biofilm development. Interdigitated electrodes (IDEs) with 29-μm spacing between 22-μm-wide electrodes, were used as a platform where the effect of localised, high-strength electric fields could be tested. Alternating current, square-wave pulses were applied to the IDEs in 1 sec intervals. A two-level, three-variable factorial design experiment was used to detect the effects of applied voltage, frequency, and pulse duty ratio (i.e. percentage of pulsing time over one cycle) on the inhibition of biofilm formation. The observations indicated that a pulse configuration of 1% duty ratio, 5 V, and 200 Hz frequency reduced the area of the electrodes covered by biofilm by 50%. In general, the application of low-duty ratio pulses had a positive effect on preventing biofouling. Comparatively, frequency and applied voltage were observed to have less influence on biofouling.Keywords
This publication has 32 references indexed in Scilit:
- Electric block current induced detachment from surgical stainless steel and decreased viability of Staphylococcus epidermidisBiomaterials, 2005
- Pulsed Ohmic Heating–A Novel Technique for Minimization of Electrochemical Reactions During ProcessingJournal of Food Science, 2005
- Assessment of the Ability of the Bioelectric Effect To Eliminate Mixed-Species BiofilmsApplied and Environmental Microbiology, 2005
- A Radio Frequency Electric Current Enhances Antibiotic Efficacy against Bacterial BiofilmsAntimicrobial Agents and Chemotherapy, 2004
- Electric Current-Induced Detachment of Staphylococcus epidermidis Biofilms from Surgical Stainless SteelApplied and Environmental Microbiology, 2004
- Inactivation of Vibrio parahaemolyticus in Effluent Seawater by Alternating-Current TreatmentApplied and Environmental Microbiology, 2004
- Thermal and nonthermal mechanisms of interaction of radio-frequency energy with biological systemsIEEE Transactions on Plasma Science, 2000
- Nanoscaled interdigitated electrode arrays for biochemical sensorsSensors and Actuators B: Chemical, 1998
- The effect of pulsed electric fields on biological cells: experiments and applicationsIEEE Transactions on Plasma Science, 1997
- Molecular approaches to nontoxic antifoulingInvertebrate Reproduction & Development, 1992