Calibration of entrance dose measurement for an in vivo dosimetry programme
- 1 November 1995
- journal article
- Published by Wiley in Australasian Radiology
- Vol. 39 (4), 369-374
- https://doi.org/10.1111/j.1440-1673.1995.tb00314.x
Abstract
An increasing number of cancer treatment centres are using in vivo dosimetry as a quality assurance tool for verifying dosimetry as either the entrance or exit surface of the patient undergoing external beam radiotherapy. Equipment is usually limited to either thermoluminescent dosimeters (TLD) or semiconductor detectors such as p-type diodes. The semiconductor detector is more popular than the TLD due to the major advantage of real time analysis of the actual dose delivered. If a discrepancy is observed between the calculated and the measured entrance dose, it is possible to eliminate several likely sources of errors by immediately verifying all treatment parameters. Five Scanditronix EDP-10 p-type diodes were investigated to determine their calibration and relevant correction factors for entrance dose measurements using a Victoreen White Water-RW3 tissue equivalent phantom and a 6 MV photon beam from a Varian Clinac 2100C linear accelerator. Correction factors were determined for individual diodes for the following parameters: source to surface distance (SSD), collimator size, wedge, plate (tray) and temperature. The directional dependence of diode response was also investigated. The SSD correction factor (CSSD) was found to increase by approximately 3% over the range of SSD from 80 to 130 cm. The correction factor for collimator size (Cfield) also varied by approximately 3% between 5 x 5 and 40 x 40 cm2. The wedge correction factor (Cwedge) and plate correction factor (Cplate) were found to be a function of collimator size. Over the range of measurement, these factors varied by a maximum of 1 and 1.5%, respectively. The Cplate variation between the solid and the drilled plates under the same irradiation conditions was a maximum of 2.4%. The diode sensitivity demonstrated an increase with temperature. A maximum of 2.5% variation for the directional dependence of diode response was observed for angle of +/- 60 degrees. In conclusion, in vivo dosimetry is an important and reliable method for checking the dose delivered to the patient. Preclinical calibration and determination of the relevant correction factors for each diode are essential in order to achieve a high accuracy of dose delivered to the patient.Keywords
This publication has 9 references indexed in Scilit:
- Performance of New Scanditronix Semiconductor Detectors for in Vivo DosimetryActa Oncologica, 1995
- Linearity with dose rate of low resistivity p-type silicon semiconductor detectorsPhysics in Medicine & Biology, 1993
- Correlation between temperature and dose rate dependence of semiconductor response; influence of accumulated doseRadiotherapy and Oncology, 1990
- Quality assurance in radiotherapy by in vivo dosimetry. 1. Entrance dose measurements, a reliable procedureRadiotherapy and Oncology, 1990
- Characteristics of silicon diodes as patient dosemeters in external radiation therapyRadiotherapy and Oncology, 1988
- General specifications for silicon semiconductors for use in radiation dosimetryPhysics in Medicine & Biology, 1987
- When and how can we improve precision in radiotherapy?Radiotherapy and Oncology, 1984
- Effects of radiation damage on p-type silicon detectorsPhysics in Medicine & Biology, 1983
- DOSE, TIME, VOLUME RELATIONSHIPS IN SQUAMOUS CELL CARCINOMA OF THE SUPRAGLOTTIC LARYNXAmerican Journal of Roentgenology, 1970