Accuracy of Respiratory Inductive Plethysmograph over Wide Range of Rib Cage and Abdominal Compartmental Contributions to Tidal Volume in Normal Subjects and in Patients with Chronic Obstructive Pulmonary Disease
- 31 July 1984
- journal article
- research article
- Published by American Thoracic Society in American Review of Respiratory Disease
- Vol. 130 (2), 171-174
- https://doi.org/10.1164/arrd.1984.130.2.171
Abstract
The accuracy of the respiratory inductive plethysmograph in the supine position to spirometry was assessed. By the 2-body position, least squares calibration and single-body position, isovolume calibration procedures. The comparison was carried out simultaneously in normal subjects breathing naturally and with voluntarily controlled abdominal or thoracic breathing, and in patients with CPOD [chronic obstructive pulmonary disease] breathing naturally and with voluntarily controlled abdominal breathing patterns. There was no significant difference in estimation of tidal volume between the 2 calibration procedures for the various breathing patterns. There was greater deviation from spirometric tidal volume values for both calibration methods in patients with COPD during abdominal than during natural breathing. In the normal subjects, agreement between the rib cage and abdominal partitioning of tidal volume for both calibration methods was good, but in the patients with COPD there was greater variability. In normal subjects, over a wide range of rib cage and abdominal compartmental contributions to tidal volume, either calibration procedure appears satisfactory. For patients with COPD, if large changes occur in the distribution of rib cage and abdominal contributions to tidal volume, then validation of respiratory inductive plethysmography to spirometry must be rechecked.This publication has 5 references indexed in Scilit:
- Validation of Respiratory Inductive Plethysmography in Patients with Pulmonary DiseaseChest, 1983
- POSTURAL CHANGES IN RIB CAGE AND ABDOMINAL VOLUME-MOTION COEFFICIENTS AND THEIR EFFECT ON THE CALIBRATION OF A RESPIRATORY INDUCTANCE PLETHYSMOGRAPHPublished by Elsevier ,1983
- VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY USING DIFFERENT CALIBRATION PROCEDURESPublished by Elsevier ,1982
- NON-INVASIVE MEASUREMENT OF VENTILATION DURING EXERCISE USING A RESPIRATORY INDUCTIVE PLETHYSMOGRAPH .1.Published by Elsevier ,1980
- Measurement of the separate volume changes of rib cage and abdomen during breathingJournal of Applied Physiology, 1967