3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent
- 3 March 2004
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 14 (7), 1291-1296
- https://doi.org/10.1007/s00330-004-2282-8
Abstract
The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40°; voxel size: 1.3×2.5×4.0 mm3; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40°; voxel size: 0.8×1.0×1.6 mm3) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer.Keywords
This publication has 19 references indexed in Scilit:
- MR-Angiographie der Koronararterien: Vergleich des Blutpoolkontrastmittels Gadomer mit Gd-DTPA am SchweinRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Assessment of lung ventilation by MR imaging: current status and future perspectivesEuropean Radiology, 2002
- Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation‐perfusion scintigraphy: An intra‐modality and inter‐modality agreement studyJournal of Magnetic Resonance Imaging, 2002
- Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigsEuropean Radiology, 2002
- Prospective comparison of MR lung perfusion and lung scintigraphyJournal of Magnetic Resonance Imaging, 1999
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- Diagnosis of Pulmonary Embolism with Magnetic Resonance AngiographyNew England Journal of Medicine, 1997
- Pulmonary perfusion: Qualitative assessment with dynamic contrast‐enhanced MRI using ultra‐short TE and inversion recovery turbo FLASHMagnetic Resonance in Medicine, 1996
- Magnetic Resonance Imaging Detection of an Experimental Pulmonary Perfusion Deficit Using a Macromolecular Contrast Agent Polylysine-Gadolinium-DTPA40Investigative Radiology, 1992