The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery
- 1 March 1994
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 95 (3), 1641-1649
- https://doi.org/10.1121/1.408550
Abstract
The purpose of this study was to test the concept of using calculated thermal dose as a predictor for the necrosed tissue volume. A parametric study was conducted where the sonication parameters (pulse duration, power), transducer parameters (frequency, F number) and tissue properties (perfusion rate, attenuation) were varied and their effect on the lesion size was investigated. In vivo experiments where a focused ultrasound beam was used to induce tissue necrosis in thigh muscle of dog and rabbit were also conducted to obtain the reliability of the predictions. The experimental and simulated lesion sizes compared well. From the parametric study the threshold intensity for 1‐ and 5‐s sonications were found to be about 1000 and 400 W/cm2, respectively. It was found that the lesion size was practically perfusion independent for pulses 5 s or shorter. The lesion size increases with increased pulse duration, acoustical power, and F number, but decreases with increased frequency provided that the focal intensity is kept constant. It was found also that the deeper the focus is in the tissue, the smaller the frequency range that causes selective tissue necrosis in the focal zone.Keywords
This publication has 9 references indexed in Scilit:
- High intensity focused ultrasound for the treatment of rat tumoursPhysics in Medicine & Biology, 1991
- Time-temperature analysis of cell killing of BHK cells heated at temperatures in the range of 43.5°C to 57.0°CInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Histopathological Changes in the Skin and Subcutaneous Tissues of Mouse Legs after Treatment with HyperthermiaPathology - Research and Practice, 1990
- Effects of physical parameters on high temperature ultrasound hyperthermiaJapanese Journal of Clinical Oncology, 1990
- Chronic Histological Effects of Ultrasonic Hyperthermia on Normal Feline Brain TissueRadiation Research, 1986
- Thermal dose determination in cancer therapyInternational Journal of Radiation Oncology*Biology*Physics, 1984
- THE EFFECTS OF HYPERTHERMIA ON NORMAL MESENCHYMAL TISSUES - APPLICATION OF A HISTOLOGIC GRADING SYSTEM1983
- Finite amplitude effects on the thresholds for lesion production in tissues by unfocused ultrasoundThe Journal of the Acoustical Society of America, 1981
- Thresholds for Focal Ultrasonic Lesions in Rabbit Kidney, Liver, and TesticleIEEE Transactions on Biomedical Engineering, 1977