Brain Oxygen, CO2, pH, and Temperature Monitoring
- 1 December 1995
- journal article
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 37 (6), 1168
- https://doi.org/10.1097/00006123-199512000-00017
Abstract
Currently, no ideal method exists for monitoring the injured brain. Recently, a single, compact, fiberoptic sensor has become available for measuring oxygen, CO2, pH and temperature in blood. We have adapted this instrument for continuous use in brain tissue to measure oxygen tension, carbon dioxide tension (pCO2), pH, and temperature. To evaluate this new technique, we produced hypercapnia, hypocapnia, intracranial pressure increase, and hypoxemia in seven normal cats. In an additional six animals, sensors were placed within a zone of focal brain ischemia induced by occluding the left middle cerebral artery. The sensor readings were compared with cerebral blood flow measurements, intracranial pressure, and brain histological findings. An in vitro experiment was also performed using human blood to test the accuracy of the sensor over a wide range of pCO2 and oxygen tension values. After careful precalibration and rigid cranium fixation, stable measurements could be obtained throughout the 6- to 8-hour experiments. In normal animals, brain oxygen was 42 +/- 9 mm Hg, brain CO2 was 59 +/- 14 mm Hg, brain pH was 7.0 +/- 0.2, and brain temperature was 36.7 +/- 0.7 degrees C. Hypocapnia and hypoxemia produced a significant decline in tissue oxygen (< or = 30 +/- 3 mm Hg; P < 0.001), whereas hypercapnia caused by hypoventilation and intracranial pressure increase produced a significant increase in tissue CO2 (> or = 74 +/- 4 mm Hg; P < 0.001). Focal ischemia produced a rapid 42% decline in brain oxygen (25 +/- 7 mm Hg) and a 25% increase in tissue pCO2 (71 +/- 23 mm Hg). Brain oxygen further decreased to 19 +/- 6 mm Hg toward the end of the experiment, 4 hours later. After middle cerebral artery occlusion, the regional cerebral blood flow decreased to 10 +/- 5 ml per 100 g per minute, within the 1st hour, from a baseline value of 65 +/- 15 ml per 100 g per minute. It then gradually increased to 15 +/- 5 ml per 100 g per minute by the end of the 4-hour experiment. Brain pH was closely and inversely related to brain CO2. The brain temperature in the focally ischemic tissue decreased from 36.7 +/- 0.7 to 35.5 +/- 1.6 degrees C by the end of the experiment. The in vitro experiment demonstrated good linear correlation between the sensor readings and the blood gas analysis. Continuous monitoring of oxygen, CO2, pH, and temperature in damaged or at-risk brain tissue using a single sensor is now feasible and will, thus, allow improved continuous monitoring of neurosurgical patients who are at risk of significant secondary brain damage.Keywords
This publication has 21 references indexed in Scilit:
- Hyperthermia complicates middle cerebral artery occlusion induced by an intraluminal filamentBrain Research, 1994
- Temperature Dependent Change of Apparent Diffusion Coefficient of Water in Normal and Ischemic Brain of RatsJournal of Cerebral Blood Flow & Metabolism, 1994
- Cerebrospinal Fluid pH and PCO2 Rapidly Follow Arterial Blood pH and PCO2 with Changes in VentilationNeurosurgery, 1994
- Brain pHi, cerebral blood flow, and NADH fluorescence during severe incomplete global ischemia in rabbits.Stroke, 1993
- Continuous monitoring of jugular venous oxygen saturation in head-injured patientsJournal of Neurosurgery, 1992
- Cerebral arteriovenous oxygen difference as an estimate of cerebral blood flow in comatose patientsJournal of Neurosurgery, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Cerebral blood flow and metabolism in comatose patients with acute head injuryJournal of Neurosurgery, 1984
- Brain oxygen autoregulation: A protective reflex to hypoxia?Microvascular Research, 1974
- Regional cerebral blood flow, intracranial pressure, and brain metabolism in comatose patientsJournal of Neurosurgery, 1973