Effects of exercise on aortic input impedance and pressure wave forms in normal humans.
- 1 March 1981
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 48 (3), 334-343
- https://doi.org/10.1161/01.res.48.3.334
Abstract
The effects of supine bicycle exercise on the input impedance of the ascending aorta were studied in thirteen male subjects undergoing cardiac catheterization, but in whom no cardiovascular disease was found. Ascending aortic flow velocity and pressure were recorded simultaneously from a multisensor catheter with an electromagnetic flow velocity probe and a pressure sensor mounted at the same location. A second pressure sensor at the catheter tip provided left ventricular pressure. Fick cardiac outputs were used to scale the velocity signal to instantaneous volumetric flow. Input impedance was calculated from 10 harmonics of aortic pressure and flow. For each subject, impedance moduli and phases from a minimum of 15 beats during rest and exercise were averaged. Peripheral resistance decreased from a resting value of 1142 +/- 51 (+/- SE) dynes sec/cm5 to 712 +/- 39 dynes sec/cm5 during exercise. Characteristic impedance remained unchanged with a resting value of 47 +/- 4 dynes sec/cm5 and an exercise value of 45 +/- 4 dynes sec/cm5. These results were associated with an increase in aortic pressure (96 +/- 2 to 111 +/- 2 mm Hg) and pulse wave velocity implying a decrease in aortic compliance. An increase in aortic cross-sectional area apparently offsets the effects of these changes in compliance and pulse wave velocity to result in an unchanged characteristic impedance. The increase in pulse wave velocity caused wave reflections to occur earlier during exercise, but the general characteristics of the pressure wave shapes remained unchanged.This publication has 22 references indexed in Scilit:
- Evaluation of a new catheter‐mounted electromagnetic velocity sensor during cardiac catheterizationCatheterization and Cardiovascular Diagnosis, 1980
- Evaluation of the elasticity and characteristic impedance of the ascending aorta in manCardiovascular Research, 1978
- Physiologic signal acquisition and processing for human hemodynamic research in a clinical cardiac-catheterization laboratoryProceedings of the IEEE, 1977
- A stable ultraminiature catheter-tip pressure transducerMedical & Biological Engineering & Computing, 1973
- Vascular Input ImpedancePublished by Elsevier ,1972
- Pressure-flow relationships and vascular impedance in manCardiovascular Research, 1970
- Velocity Distribution and Transition in the Arterial SystemPublished by Wiley ,1969
- IMPEDANCE OF CERTAIN LARGE BLOOD VESSELS IN MANAnnals of the New York Academy of Sciences, 1964