The use of partial discharge measurements to assess the condition of rotating machine insulation
- 1 July 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 12 (4), 23-27
- https://doi.org/10.1109/57.526944
Abstract
This article reviews some of the recent improvements in measurement technology that have enabled on-line PD testing to be applied to a significant percentage of high voltage motors and generators in use in North America today.Keywords
This publication has 7 references indexed in Scilit:
- Development of an expert system to diagnose motor insulation conditionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Unusual PD pulse phase distributions in operating rotating machinesIEEE Transactions on Dielectrics and Electrical Insulation, 1995
- Use of a mixed-Weibull distribution for the identification of PD phenomena [corrected version]IEEE Transactions on Dielectrics and Electrical Insulation, 1995
- Computer-aided measurement of partial discharges in HV equipmentIEEE Transactions on Electrical Insulation, 1993
- Novel Partial Discharge Measurement Computer-Aided Measuremnet SystemsIEEE Transactions on Electrical Insulation, 1986
- A Simple Pulse-Height Analyzer for Partial-Discharge-Rate MeasurementsIEEE Transactions on Instrumentation and Measurement, 1969
- Detection of Slot Discharges in High-Voltage Stator Windings During OperationTransactions of the American Institute of Electrical Engineers, 1951