Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution
- 1 January 1999
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (3), 781-799
- https://doi.org/10.1088/0031-9155/44/3/019
Abstract
Developments in positron emission tomography (PET) technology have resulted in systems with finer detector elements designed to further improve spatial resolution. However, there is a limit to what extent reducing detector element size will improve spatial resolution in PET. The spatial resolution of PET imaging is limited by several other factors, such as annihilation photon non-collinearity, positron range, off-axis detector penetration, detector Compton scatter, undersampling of the signal in the linear or angular directions for the image reconstruction process, and patient motion. The overall spatial resolution of the systems is a convolution of these components. Of these other factors that contribute to resolution broadening, perhaps the most uncertain, poorly understood, and, for certain isotopes, the most dominant effect is from positron range. To study this latter effect we have developed a Monte Carlo simulation code that models positron trajectories and calculates the distribution of the end point coordinates in water for the most common PET isotopes used: F, N, C and O. In this work we present some results from these positron trajectory studies and calculate what effect positron range has on the overall PET system spatial resolution, and how this influences the choice of PET system design parameters such as detector element size and system diameter. We found that the fundamental PET system spatial resolution limit set from detector size, photon non-collinearity and positron range alone varied from nearly 1 mm FWHM (2 mm FWTM) for a 10-20 cm diameter system typical for animal studies with F to roughly 4 mm FWHM (7 mm FWTM) for an 80 cm diameter system typical for human imaging using O.Keywords
This publication has 19 references indexed in Scilit:
- Performance evaluation of the whole-body PET scanner ECAT EXACT HR/sup +/ following the IEC standardIEEE Transactions on Nuclear Science, 1997
- Investigation of LSO crystals for high spatial resolution positron emission tomographyIEEE Transactions on Nuclear Science, 1997
- Optical fiber readout of scintillator arrays using a multi-channel PMT: a high resolution PET detector for animal imagingIEEE Transactions on Nuclear Science, 1996
- Mathematical Removal of Positron Range Blurring in High Resolution TomographyIEEE Transactions on Nuclear Science, 1986
- A Simulation Study of a Method to Reduce Positron Annihilation Spread Distributions Using a Strong Magnetic Field in Positron Emission TomographyIEEE Transactions on Nuclear Science, 1986
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1982
- Shapes of Beta-Ray SpectraReviews of Modern Physics, 1968
- Molière's Theory of Multiple ScatteringPhysical Review B, 1953
- Range-Energy Relations for Electrons and the Determination of Beta-Ray End-Point Energies by AbsorptionReviews of Modern Physics, 1952
- On the Angular Distribution of Two-Photon Annihilation RadiationPhysical Review B, 1950