Fast oxygen‐enhanced multislice imaging of the lung using parallel acquisition techniques
- 19 May 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (6), 1317-1325
- https://doi.org/10.1002/mrm.20495
Abstract
The purpose of this study was to evaluate an optimized multislice acquisition technique for oxygen‐enhanced MRI of the lung using slice‐selective inversion and refocusing pulses in combination with parallel imaging. An inversion recovery HASTE sequence was implemented with respiratory triggering to perform imaging in end‐expiration and with ECG triggering to avoid image acquisition during the systolic phase. Inversion pulses and the readout of echo trains could be interleaved to decrease acquisition time. The sequence was evaluated in 15 healthy volunteers, comparing three acquisition schemes: (1) acquisition of four slices without parallel imaging; (2) acquisition of four slices with parallel imaging; (3) acquisition of six slices with parallel imaging. These multislice acquisitions were repeated 80 times with alternating inhalation of room air and oxygen. The oxygen‐induced signal increase showed no significant difference with and without parallel imaging. However, only with parallel imaging did the interleaved acquisition of six or more slices become possible, thus enabling a more complete anatomic coverage of the lung. The average required end‐expiration time per repetition to acquire six slices could be significantly reduced from 4112 ms without to 2727 ms with parallel imaging. Total acquisition time varied between 8 and 13 min depending on the respiratory frequency. Magn Reson Med 53:1317–1325, 2005.Keywords
This publication has 17 references indexed in Scilit:
- Resolution enhancement in lung 1H imaging using parallel imaging methodsMagnetic Resonance in Medicine, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Dynamic oxygen‐enhanced MRI reflects diffusing capacity of the lungMagnetic Resonance in Medicine, 2002
- Pulmonary Diffusing Capacity: Assessment with Oxygen-enhanced Lung MR Imaging—Preliminary FindingsRadiology, 2002
- Oxygen-Enhanced MR Ventilation Imaging of the LungAmerican Journal of Roentgenology, 2001
- Optimization and evaluation of the signal intensity change in multisection oxygen-enhanced MR lung imagingMagnetic Resonance in Medicine, 2000
- Effect of respiratory phases on MR lung signal intensity and lung conspicuity using segmented multiple inversion recovery turbo spin echo (MIR-TSE)Magnetic Resonance in Medicine, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Oxygen enhanced MR ventilation imaging of the lungMagnetic Resonance Materials in Physics, Biology and Medicine, 1998
- Noninvasive assessment of regional ventilation in the human lung using oxygen–enhanced magnetic resonance imagingNature Medicine, 1996