Fibrosis in the transplanted heart and its relation to donor ischemic time. Assessment with polarized light microscopy and digital image analysis.
- 1 March 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 81 (3), 949-958
- https://doi.org/10.1161/01.cir.81.3.949
Abstract
Long-distance procurement of cardiac allografts is commonly used to increase the supply of donor organs but has recently been associated with the development of impaired diastolic function. Therefore, the effect of the total ischemic duration on myocardial fibrosis was quantitatively evaluated in 36 cardiac transplant recipients in whom the ischemic time ranged from 70 to 363 (mean, 189 +/- 83) minutes. Interstitial collagen was quantified with polarization microscopy and digital image analysis in 115 endomyocardial biopsy specimens taken 5-10 days after surgery. The technique, developed for this study, showed excellent correlation with hydroxyproline analysis (r = 0.98, p less than 0.001). Collagen volume fraction in biopsy specimens from the transplanted hearts was significantly greater than that in biopsy samples from seven normal, age-matched autopsy hearts (4.7 +/- 1.9% vs. 2.9 +/- 0.6%, p less than 0.02). The degree of fibrosis correlated with the total ischemic time (r = 0.60, p less than 0.001). Donor age ranged from 10 to 51 years and did not correlate with the degree of fibrosis. No relation was found between the corresponding collagen content and right atrial pressure, pulmonary artery wedge pressure, or cardiac output measured at the time of biopsy. Myocyte damage was observed in eight of the 36 patients and was characterized by a striking loss of muscle birefringence. We conclude that cardiac allograft fibrosis may be identified shortly after transplantation and is dependent on the total ischemic duration.This publication has 17 references indexed in Scilit:
- Diastolic function after cardiac and heart-lung transplantation.Heart, 1989
- Hemodynamic profiles at rest and during supine exercise after orthotopic cardiac transplantationThe American Journal of Cardiology, 1988
- Interobserver variability in the pathologic interpretation of endomyocardial biopsy results.Circulation, 1987
- A biochemical method for the quantitation of myocardial scarring after experimental coronary artery occlusionJournal of Molecular and Cellular Cardiology, 1986
- Long-term hemodynamic follow-up of cardiac transplant patients treated with cyclosporine and prednisone.Circulation, 1985
- Heart transplant pathology: the British experience.Journal of Clinical Pathology, 1985
- Human cardiac transplantation — evaluation of morphological changes in serial endomyocardial biopsiesPathology - Research and Practice, 1985
- The effect of exercise and atrial pacing on left ventricular volume and contractility in patients with innervated and denervated hearts.Circulation, 1978
- The incidence and significance of contraction bands in endomyocardial biopsies from normal human heartsAmerican Heart Journal, 1978