Sources of error in intraocular lens power calculation
Top Cited Papers
- 1 March 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (3), 368-376
- https://doi.org/10.1016/j.jcrs.2007.10.031
Abstract
Hed literature to the extent available. To evaluate their influence on refraction, thick-lens ray tracing that allowed for asphericity was used. The numerical partial derivative of each parameter with respect to spectacle refraction was calculated. The product of the partial derivative and the SD for a parameter equates to its SD, expressed as spectacle diopters, which squared is the variance. The error contribution of a parameter is its variance relative to the sum of the variances of all parameters. RESULTS: Preoperative estimation of postoperative intraocular lens (IOL) position, postoperative refraction determination, and preoperative axial length (AL) measurement were the largest contributors of error (35%, 27%, and 17%, respectively), with a mean absolute error (MAE) of 0.6 diopter (D) for an eye of average dimensions. Pupil size variation in the population accounted for 8% of the error, and variability in IOL power, 1%. CONCLUSIONS: Improvement in refractive outcome requires better methods for predicting the postoperative IOL position. Measuring AL by partial coherence interferometry may be of benefit. Autorefraction increases precision in outcome measurement. Reducing these 3 major error sources with means available today reduces the MAE to 0.4 D. Using IOLs that compensate for the spherical aberration of the cornea would eliminate the influence of pupil size. Further improvement would require measuring the asphericity of the anterior surface and radius of the posterior surface of the cornea....Keywords
This publication has 19 references indexed in Scilit:
- Assessment of pupil size under different light intensities using the Procyon pupillometerJournal of Cataract & Refractive Surgery, 2006
- The shape of the anterior and posterior surface of the aging human corneaVision Research, 2005
- Use of Optical Coherence Tomography to Assess Variations in Macular Retinal Thickness in MyopiaInvestigative Opthalmology & Visual Science, 2005
- The Dubbelman eye model analysed by ray tracing through aspheric surfacesOphthalmic and Physiological Optics, 2005
- Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photographyActa Ophthalmologica Scandinavica, 2002
- Multicenter biometry study of 1 pair of eyesJournal of Cataract & Refractive Surgery, 2001
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisAlbrecht von Graefes Archiv für Ophthalmologie, 2000
- The Repeatability of Automated and Clinician RefractionOptometry and Vision Science, 1998
- Accuracy in determining intraocular lens dioptric power assessed by interlaboratory testsJournal of Cataract & Refractive Surgery, 1996
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 1992