Correlation between optics quality of multifocal intraocular lenses and visual acuity
- 1 April 2010
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (4), 557-562
- https://doi.org/10.1016/j.jcrs.2009.10.046
Abstract
To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Fundación Oftalmológica del Mediterráneo, Valencia, Spain. Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the "average modulation" of the IOL was assessed. The pupil diameter and patient age were similar between the 3 IOL groups (20 eyes each). A difference in average modulation (ie, optics quality) up to 15% did not produce significant differences in mean visual acuity between 2 groups; however, there was a significant difference in mean visual acuity between 2 groups when the average modulation values differed by at least 25%. The slope of the linear correlation between visual acuity and average modulation was 0.018 (r(2) = 0.91) under photopic conditions and 0.024 (r(2) = 0.089) under mesopic conditions. There was a strong linear correlation between IOL optics quality and visual acuity with distance correction under photopic conditions with a pupil of approximately 3.5 mm in a cohort in which the patient age was controlled. The correlation was similar under mesopic conditions. The eye's tolerance to modulation transfer function decay was approximately 15% of the average modulation value.Keywords
This publication has 29 references indexed in Scilit:
- Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lensJournal of Cataract & Refractive Surgery, 2009
- Outcomes of laser refractive surgery for myopiaJournal of Cataract & Refractive Surgery, 2009
- Visual function after implantation of an aspheric bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2009
- Maximizing Satisfaction with Presbyopia-Correcting Intraocular Lenses: The Missing LinksAmerican Journal of Ophthalmology, 2008
- Astigmatism management in cataract surgery with the AcrySof toric intraocular lensJournal of Cataract & Refractive Surgery, 2008
- Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or youngerJournal of Cataract & Refractive Surgery, 2008
- Image quality with multifocal intraocular lenses and the effect of pupil sizeJournal of Cataract & Refractive Surgery, 2007
- Accommodative intraocular lenses: considerations on use, function and designCurrent Opinion in Opthalmology, 2007
- Functional Outcome and Patient Satisfaction After Artisan Phakic Intraocular Lens Implantation for the Correction of MyopiaAmerican Journal of Ophthalmology, 2006
- Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitroJournal of Cataract & Refractive Surgery, 2005