Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Top Cited Papers
- 30 October 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 467 (4), 1074-1082
- https://doi.org/10.1007/s11999-008-0594-8
Abstract
Skeletal muscle architecture is defined as the arrangement of fibers in a muscle and functionally defines performance capacity. Architectural values are used to model muscle-joint behavior and to make surgical decisions. The two most extensively used human lower extremity data sets consist of five total specimens of unknown size, gender, and age. Therefore, it is critically important to generate a high-fidelity human lower extremity muscle architecture data set. We disassembled 27 muscles from 21 human lower extremities to characterize muscle fiber length and physiologic cross-sectional area, which define the excursion and force-generating capacities of a muscle. Based on their architectural features, the soleus, gluteus medius, and vastus lateralis are the strongest muscles, whereas the sartorius, gracilis, and semitendinosus have the largest excursion. The plantarflexors, knee extensors, and hip adductors are the strongest muscle groups acting at each joint, whereas the hip adductors and hip extensors have the largest excursion. Contrary to previous assertions, two-joint muscles do not necessarily have longer fibers than single-joint muscles as seen by the similarity of knee flexor and extensor fiber lengths. These high-resolution data will facilitate the development of more accurate musculoskeletal models and challenge existing theories of muscle design; we believe they will aid in surgical decision making.Keywords
This publication has 34 references indexed in Scilit:
- Comment on the ClassicsClinical Orthopaedics and Related Research, 2006
- Pronator Teres Is an Appropriate Donor Muscle for Restoration of Wrist and Thumb ExtensionThe Journal of Hand Surgery, 2005
- Sarcomere length measurement permits high resolution normalization of muscle fiber length in architectural studiesJournal of Experimental Biology, 2005
- Density and hydration of fresh and fixed human skeletal muscleJournal of Biomechanics, 2004
- Mechanical considerations in the design of surgical reconstructive proceduresJournal of Biomechanics, 2002
- In‐series fiber architecture in long human musclesJournal of Morphology, 1993
- Architecture of selected wrist flexor and extensor musclesThe Journal of Hand Surgery, 1990
- Muscle fiber architecture in the human lower limbJournal of Biomechanics, 1990
- Electromyographic (EMG) amplitude patterns in the proximal and distal compartments of the cat semitendinosus during various motor tasksBrain Research, 1989
- Architecture of the hind limb muscles of cats: Functional significanceJournal of Morphology, 1982