Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
Open Access
- 1 January 2021
- journal article
- research article
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 64 (1), 13-22
- https://doi.org/10.3340/jkns.2020.0186
Abstract
Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.Keywords
Funding Information
- National Research Foundation of Korea (2017R1C1B5077022)
- Ministry of Science, Technology and Information
This publication has 17 references indexed in Scilit:
- The Variable Ellipsoid Modeling Technique as a Verification Method for the Treatment Planning System of Gamma Knife RadiosurgeryJournal of Korean Neurosurgical Society, 2010
- A simple method of independent treatment time verification in gamma knife radiosurgery using integral doseMedical Physics, 2004
- An algorithm for independent verification of Gamma Knife™ treatment plansMedical Physics, 2004
- An Evaluation of the Model C Gamma Knife with Automatic Patient PositioningNeurosurgery, 2002
- An Evaluation of the Model C Gamma Knife with Automatic Patient PositioningNeurosurgery, 2002
- A formalism for independent checking of Gamma Knife dose calculationsMedical Physics, 2001
- GammaPlan®-Leksell Gamma Knife® radiosurgery treatment planning verification methodMedical Physics, 2000
- Fast verification of Gamma Knife™ treatment plansJournal of Applied Clinical Medical Physics, 2000
- Quality assurance for gamma knife stereotactic radiosurgeryInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Physics of gamma knife approach on convergent beams in stereotactic radiosurgeryInternational Journal of Radiation Oncology*Biology*Physics, 1990