Routine clinical brain MRI sequences for use at 3.0 Tesla
Open Access
- 21 June 2005
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 22 (1), 13-22
- https://doi.org/10.1002/jmri.20356
Abstract
Purpose To establish image parameters for some routine clinical brain MRI pulse sequences at 3.0 T with the goal of maintaining, as much as possible, the well‐characterized 1.5‐T image contrast characteristics for daily clinical diagnosis, while benefiting from the increased signal to noise at higher field. Materials and Methods A total of 10 healthy subjects were scanned on 1.5‐T and 3.0‐T systems for T1 and T2 relaxation time measurements of major gray and white matter structures. The relaxation times were subsequently used to determine 3.0‐T acquisition parameters for spin‐echo (SE), T1‐weighted, fast spin echo (FSE) or turbo spin echo (TSE), T2‐weighted, and fluid‐attenuated inversion recovery (FLAIR) pulse sequences that give image characteristics comparable to 1.5 T, to facilitate routine clinical diagnostics. Application of the routine clinical sequences was performed in 10 subjects, five normal subjects and five patients with various pathologies. Results T1 and T2 relaxation times were, respectively, 14% to 30% longer and 12% to 19% shorter at 3.0 T when compared to the values at 1.5 T, depending on the region evaluated. When using appropriate parameters, routine clinical images acquired at 3.0 T showed similar image characteristics to those obtained at 1.5 T, but with higher signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR), which can be used to reduce the number of averages and scan times. Recommended imaging parameters for these sequences are provided. Conclusion When parameters are adjusted for changes in relaxation rates, routine clinical scans at 3.0 T can provide similar image appearance as 1.5 T, but with superior image quality and/or increased speed. J. Magn. Reson. Imaging 2005;22:13–22.Keywords
This publication has 18 references indexed in Scilit:
- High-Resolution Three-Dimensional Contrast-Enhanced Blood Oxygenation Level-Dependent Magnetic Resonance Venography of Brain Tumors at 3 Tesla: First Clinical Experience and Comparison with 1.5 TeslaInvestigative Radiology, 2003
- Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological ImagingInvestigative Radiology, 2003
- Effect of Contrast Dose and Field Strength in the Magnetic Resonance Detection of Brain MetastasesInvestigative Radiology, 2003
- High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experienceMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- MR Imaging of Human Brain at 3.0 T: Preliminary Report on Transverse Relaxation Rates and Relation to Estimated Iron ContentRadiology, 1999
- Experimental determination of the BOLD field strength dependence in vessels and tissueMagnetic Resonance in Medicine, 1997
- Nuclear relaxation of human brain gray and white matter: Analysis of field dependence and implications for MRIMagnetic Resonance in Medicine, 1990
- What is the Correct Value for the Brain-Blood Partition Coefficient for Water?Journal of Cerebral Blood Flow & Metabolism, 1985
- A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and ageMedical Physics, 1984