Multimodality image registration by maximization of mutual information
- 1 April 1997
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 16 (2), 187-198
- https://doi.org/10.1109/42.563664
Abstract
A new approach to the problem of multimodality medical image registration is proposed, using a basic concept from information theory, mutual information (MI), or relative entropy, as a new matching criterion. The method presented in this paper applies MI to measure the statistical dependence or information redundancy between the image intensities of corresponding voxels in both images, which is assumed to be maximal if the images are geometrically aligned. Maximization of MI is a very general and powerful criterion, because no assumptions are made regarding the nature of this dependence and no limiting constraints are imposed on the image content of the modalities involved. The accuracy of the MI criterion is validated for rigid body registration of computed tomography (CT), magnetic resonance (MR), and photon emission tomography (PET) images by comparison with the stereotactic registration solution, while robustness is evaluated with respect to implementation issues, such as interpolation and optimization, and image content, including partial overlap and image degradation. Our results demonstrate that subvoxel accuracy with respect to the stereotactic reference solution can be achieved completely automatically and without any prior segmentation, feature extraction, or other preprocessing steps which makes this method very well suited for clinical applications.Keywords
This publication has 19 references indexed in Scilit:
- A strategy for automated multimodality image registration incorporating anatomical knowledge and imager characteristicsPublished by Springer Nature ,2005
- Multi-modal volume registration by maximization of mutual informationMedical Image Analysis, 1996
- Multi-modality image registration by maximization of mutual informationPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1996
- Comparison of Feature-Based Matching of CT and MR Brain ImagesLecture Notes in Computer Science, 1995
- On the problem of geometric distortion in magnetic resonance images for stereotactic neurosurgeryMagnetic Resonance Imaging, 1994
- Voxel similarity measures for automated image registrationPublished by SPIE-Intl Soc Optical Eng ,1994
- Pseudocorrelation: A fast, robust, absolute, grey-level image alignment algorithmMedical Physics, 1994
- MRI-PET Registration with Automated AlgorithmJournal of Computer Assisted Tomography, 1993
- A survey of image registration techniquesACM Computing Surveys, 1992
- Registration of multimodality medical images using a region overlap criterionCVGIP: Graphical Models and Image Processing, 1992