Diastolic disease in left ventricular hypertrophy: comparison of M mode and Doppler echocardiography for the assessment of rapid ventricular filling.
Open Access
- 1 April 1991
- Vol. 65 (4), 194-200
- https://doi.org/10.1136/hrt.65.4.194
Abstract
OBJECTIVE--To investigate possible discrepancies between M mode and Doppler echocardiography in assessing early diastolic filling. DESIGN--Forty seven patients with left ventricular hypertrophy due to aortic stenosis and 26 healthy controls with a similar age range were studied by M mode, Doppler, apexcardiography, and phonocardiography. The patients also underwent cardiac catheterisation. M mode echograms were digitised by a computer. Early diastolic filling in both groups as assessed by the two techniques was compared. SETTING--A tertiary cardiac referral centre with facilities for non-invasive and invasive investigations. SUBJECTS--Patients referred for assessment of aortic stenosis who had left ventricular hypertrophy. MAIN OUTCOME MEASURES--Filling velocities on Doppler and rates of wall thinning and dimension increase on M mode. RESULTS--Digitised M mode indices of diastolic filling (peak wall thinning rate 6.4 (3.0) v 10.0 (3.0) cm/s and peak rate of dimension increase 9.3 (3.3) v 16 (4.5) cm/s) in the patients and controls were consistently different. In contrast, the Doppler A/E ratio and peak E wave velocity were not; they varied widely among patients with left ventricular hypertrophy. In part, this variability was because the Doppler A/E ratio, but not the digitised M mode indices, was very sensitive to the abnormalities of isovolumic relaxation frequently present in left ventricular hypertrophy. The Doppler A/E ratio varied similarly with age in both normal and hypertrophied hearts; in the patients with ventricular hypertrophy the peak rate of dimension increase depended on age only, whereas the thinning rate was independent of age in both the patients and controls. Neither the A/E ratio nor the M mode indices could be related to the left ventricular end diastolic pressure or the peak aortic pressure difference. CONCLUSIONS--When Doppler and M mode techniques are used to assess rapid filling in patients with left ventricular hypertrophy the M mode indices are more consistently abnormal. The two methods measure different aspects of left ventricular diastolic function and should be regarded as complementary rather than interchangeable.Keywords
This publication has 18 references indexed in Scilit:
- Relation of filling pattern to diastolic function in severe left ventricular disease.Heart, 1990
- Phase differences between left ventricular wall motion and transmitral flow in man: evidence for involvement of ventricular restoring forces in normal rapid fillingInternational Journal of Cardiology, 1989
- Quantification of atrial contribution to left ventricular filling by pulsed Doppler echocardiography and the effect of age in normal and diseased heartsThe American Journal of Cardiology, 1987
- Determination of parameters of left ventricular diastolic filling with pulsed Doppler echocardiography: comparison with cineangiography.Circulation, 1985
- Noninvasive evaluation of left ventricular diastolic function by radionuclide angiography: limitations and applicationsInternational Journal of Cardiology, 1984
- Augmentation of atrial contribution to left ventricular inflow with aging as assessed by intracardiac doppler flowmetryThe American Journal of Cardiology, 1984
- Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method.Circulation, 1977
- Analysis of left ventricular wall movement during isovolumic relaxation and its relation to coronary artery disease.Heart, 1976
- Measurement of peak rates of left ventricular wall movement in man. Comparison of echocardiography with angiography.Heart, 1975
- Reduction in the Rate of Diastolic Descent of the Mitral Valve Echogram in Patients with Altered Left Ventricular Diastolic Pressure-Volume RelationsCirculation, 1974