Dispersion encoded full range frequency domain optical coherence tomography
- 22 December 2008
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (1), 7-24
- https://doi.org/10.1364/oe.17.000007
Abstract
We propose an iterative algorithm that exploits the dispersion mismatch between reference and sample arm in frequency-domain optical coherence tomography (FD-OCT) to effectively cancel complex conjugate mirror terms in individual A-scans and thereby generate full range tomograms. The resulting scheme, termed dispersion encoded full range (DEFR) OCT, allows distinguishing real structures from complex conjugate mirror artifacts. Even though DEFR-OCT has higher post-processing complexity than conventional FD-OCT, acquisition speed is not compromised since no additional A-scans need to be measured, thereby rendering this technique robust against phase fluctuations. The algorithm uses numerical dispersion compensation and exhibits similar resolution as standard processing. The residual leakage of mirror terms is further reduced by incorporating additional knowledge such as the power spectrum of the light source. The suppression ratio of mirror signals is more than 50 dB and thus comparable to complex FD-OCT techniques which use multiple A-scans.Keywords
This publication has 38 references indexed in Scilit:
- Full-range, high-speed, high-resolution 1-µm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eyeOptics Express, 2008
- In vivo high-contrast imaging of deep posterior eye by 1-μm swept source optical coherence tomography and scattering optical coherence angiographyOptics Express, 2007
- Autocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determinationJournal of Biomedical Optics, 2007
- Minimum distance mapping using three-dimensional optical coherence tomography for glaucoma diagnosisJournal of Biomedical Optics, 2007
- A practical approach to eliminate autocorrelation artefacts for volume-rate spectral domain optical coherence tomographyPhysics in Medicine & Biology, 2006
- Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 13 µmOptics Express, 2005
- Improved complex spectral domain OCT for in vivo eye imagingOptics Communications, 2005
- In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerveOptics Express, 2004
- Complex spectral OCT in human eye imaging in vivoOptics Communications, 2004
- Instantaneous quadrature low-coherence interferometry with 3×3 fiber-optic couplersOptics Letters, 2003