Output factor measurements for a kilovoltage x-ray therapy unit
- 1 June 2005
- journal article
- research article
- Published by Springer Science and Business Media LLC in Australasian Physics & Engineering Sciences in Medicine
- Vol. 28 (2), 115-121
- https://doi.org/10.1007/bf03178702
Abstract
Output factors at the surface for treatment cones and lead cut-outs have been measured for a Pantak Therapax SXT 150 superficial therapy unit with x-ray beam qualities from 1 to 13 mm Al HVL. A variety of phantom materials and two ionisation chambers were tested for their suitability in output factor and percentage depth dose measurement. Solid water proved a useful water-equivalent phantom material with discrepancies between measurements in water and solid water less than 2.3% for percentage depth dose and less than 0.6% for output factors. Larger measurement discrepancies were found for Plastic Water and Perspex. A PTW Markus chamber was found to compare well with a NE 2532/3 low energy chamber in percentage depth dose measurement, but discrepancies arose between the chambers in output factor measurements, up to 5% for small field sizes. Measurements indicated that the Markus chamber had an energy dependent response in the kilovoltage range, which could account for the discrepancy in output factor measurement.Keywords
This publication has 13 references indexed in Scilit:
- Air kerma calibration factors and chamber correction values for PTW soft x-ray, NACP and Roos ionization chambers at very low x-ray energiesPhysics in Medicine & Biology, 2001
- The measurement ofkchfactors for application with the IPEMB very low energy dosimetry protocolPhysics in Medicine & Biology, 2001
- AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiologyMedical Physics, 2001
- Superficial and orthovoltage x-ray beam dosimetryMedical Physics, 1998
- Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beamsPhysics in Medicine & Biology, 1997
- The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al - 4 mm Cu HVL; 10 - 300 kV generating potential)Physics in Medicine & Biology, 1996
- A comparative study of dosimetric properties of Plastic Water and Solid Water in brachytherapy applicationsMedical Physics, 1994
- Complications in low energy X-ray dosimetry caused by electron contaminationPhysics in Medicine & Biology, 1991
- The build-up of backscatter in the energy range 1 mm Al to 8 mm Al HVT (radiotherapy beams)Physics in Medicine & Biology, 1982
- De-ossification in a Lumbar Transverse ProcessThe British Journal of Radiology, 1949