Commissioning of output factors for uniform scanning proton beams
- 31 March 2011
- journal article
- Published by Wiley in Medical Physics
- Vol. 38 (4), 2299-2306
- https://doi.org/10.1118/1.3569581
Abstract
Current commercial treatment planning systems are not able to accurately predict output factors and calculate monitor units for proton fields. Patient-specific field output factors are thus determined by either measurements or empirical modeling based on commissioning data. The objective of this study is to commission output factors for uniform scanning beams utilized at the ProCure proton therapy centers. Using water phantoms and a plane parallel ionization chamber, the authors first measured output factors with a fixed 10 cm diameter aperture as a function of proton range and modulation width for clinically available proton beams with ranges between 4 and 31.5 cm and modulation widths between 2 and 15 cm. The authors then measured the output factor as a function of collimated field size at various calibration depths for proton beams of various ranges and modulation widths. The authors further examined the dependence of the output factor on the scanning area (i.e., uncollimated proton field), snout position, and phantom material. An empirical model was developed to calculate the output factor for patient-specific fields and the model-predicted output factors were compared to measurements. The output factor increased with proton range and field size, and decreased with modulation width. The scanning area and snout position have a small but non-negligible effect on the output factors. The predicted output factors based on the empirical modeling agreed within 2% of measurements for all prostate treatment fields and within 3% for 98.5% of all treatment fields. Comprehensive measurements at a large subset of available beam conditions are needed to commission output factors for proton therapy beams. The empirical modeling agrees well with the measured output factor data. This investigation indicates that it is possible to accurately predict output factors and thus eliminate or reduce time-consuming patient-specific output measurements for proton treatments.Keywords
This publication has 21 references indexed in Scilit:
- Scan pattern optimization for uniform proton beam scanningMedical Physics, 2009
- Clinical characterization of a proton beam continuous uniform scanning system with dose layer stackingMedical Physics, 2008
- A treatment planning comparison of intensity modulated photon and proton therapy for paraspinal sarcomasInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Ridge filter design for proton therapy at Hyogo Ion Beam Medical CenterPhysics in Medicine & Biology, 2003
- Proton radiation therapy (prt) for pediatric optic pathway gliomas: comparison with 3d planned conventional photons and a standard photon techniqueInternational Journal of Radiation Oncology*Biology*Physics, 1999
- Three-dimensional beam scanning for proton therapyNuclear Instruments and Methods in Physics Research, 1983
- Spot scanning system for proton radiotherapyMedical Physics, 1980
- Flattening of proton dose distributions for large‐field radiotherapyMedical Physics, 1977
- Range modulators for protons and heavy ionsNuclear Instruments and Methods, 1975
- Radiological Use of Fast ProtonsRadiology, 1946