Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose
Top Cited Papers
- 1 March 2008
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 246 (3), 742-753
- https://doi.org/10.1148/radiol.2463070989
Abstract
To retrospectively compare image quality, radiation dose, and blood vessel assessability for coronary artery computed tomographic (CT) angiograms obtained with a prospectively gated transverse (PGT) CT technique and a retrospectively gated helical (RGH) CT technique. This HIPAA-compliant study received a waiver for approval from the institutional review board, including one for informed consent. Coronary CT angiograms obtained with 64-detector row CT were retrospectively evaluated in 203 clinical patients. A routine RGH technique was evaluated in 82 consecutive patients (44 males, 38 females; mean age, 55.6 years). The PGT technique was then evaluated in 121 additional patients (71 males, 50 females; mean age, 56.7 years). All images were evaluated for image quality, estimated radiation dose, and coronary artery segment assessability. Differences in image quality score were evaluated by using a proportional odds logistic regression model, with main effects for three readers, two techniques, and four arteries. The mean effective dose for the group with the PGT technique was 2.8 mSv; this represents an 83% reduction as compared with that for the group with the RGH technique (mean, 18.4 mSv; P < .001). The image quality score for each of the arteries, as well as the overall combined score, was significantly greater for images obtained with PGT technique than for images obtained with RGH technique. The combined mean image quality score was 4.791 for images obtained with PGT technique versus 4.514 for images obtained with RGH technique (proportional odds model odds ratio, 2.8; 95% confidence interval: 1.7, 4.8). The percentage of assessable coronary artery segments was 98.6% (1196 of 1213) for images obtained with PGT technique versus 97.9% (1741 of 1778) for images obtained with RGH technique (P = .83). PGT coronary CT angiography offers improved image quality and substantially reduced effective radiation dose compared with traditional RGH coronary CT angiography.Keywords
This publication has 38 references indexed in Scilit:
- Accuracy of MSCT coronary angiography with 64-slice technology: first experienceEuropean Heart Journal, 2005
- Multislice spiral computed tomography coronary angiography in patients with stable angina pectorisJournal of the American College of Cardiology, 2004
- Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaquesJournal of the American College of Cardiology, 2004
- assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomographyJournal of the American College of Cardiology, 2004
- Estimation of Radiation Exposure in 16-Detector Row Computed Tomography of the Heart with Retrospective ECG-gatingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Advances in Cardiac Imaging with 16-Section CT SystemsAcademic Radiology, 2003
- Radiation Dose in Computed Tomography of the HeartCirculation, 2003
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CTRadiology, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002