Impact of electroosmosis on isotachophoresis in open‐tubular fused‐silica capillaries: Analysis of the evolution of a stationary steady‐state zone structure by computer simulation and experimental validation
- 1 January 1995
- journal article
- Published by Wiley in Electrophoresis
- Vol. 16 (1), 2016-2026
- https://doi.org/10.1002/elps.11501601330
Abstract
A dynamic computer model for simulation of open‐tubular capillary electrophoresis that includes in situ calculation of electroosmosis along the fusedsilica capillary column has been applied to the characterization of an anionic isotachophoretic system in presence of a cathodic electroosmotic flow. For each column segment, electroosmosis is calculated with the use of a wall mobility, the voltage gradient and the degree of dissociation of the silanol surface groups of the capillary wall. Then, the bulk capillary flow is taken to be the average of all of the segment flows and considered to represent a plug flow. This simple approach enables the combined simulation of the temporal behavior of an isotachophoretic zone structure in presence of electroosmosis. For a model anionic isotachophoretic configuration at pH 6, simulation data reveal the asymptotic formation of a stationary steady‐state zone configuration in which electrophoretic and electroosmotic zone displacements are opposite and of equal magnitude. The position of the stationary boundaries are predicted to be dependent on the selected wall pK and mobility values. For two different instruments, qualitative agreement between experimental data and simulation results obtained with a wall pK between 5 and 6 is demonstrated. However, for the two experimental setups, significant differences in electroosmotic pumping (i.e. wall mobility values) are noted.Keywords
This publication has 17 references indexed in Scilit:
- Efficient computerized data acquisition and evaluation for capillary isotachophoresis in quiescent and flowing solution with single detectors placed towards the capillary endJournal of Chromatography A, 1993
- Comparative use of three electrokinetic capillary methods for the determination of drugs in body fluidsJournal of Chromatography A, 1993
- Isotachophoresis with electroosmotic flow: open versus closed systemsJournal of Chromatography A, 1991
- Innovative development in isotachophoresis (displacement electrophoresis)Journal of Biochemical and Biophysical Methods, 1991
- Isotachophoresis in open-tubular fused-silica capillaries with on-column multi-wavelength detectionJournal of Chromatography A, 1991
- Isotachophoresis in open systems : Problems in quantitative analysisJournal of Chromatography A, 1991
- Isotachophoresis in open-tubular fused-silica capillaries : Impact of electroosmosis on zone formation and displacementJournal of Chromatography A, 1990
- Computer simulation and experimental validation of the electrophoretic behavior of proteinsAnalytical Chemistry, 1989
- Capillary isotachophoresis/mass spectrometryAnalytical Chemistry, 1989
- Electrophoresis: Mathematical Modeling and Computer SimulationScience, 1983