Genetic variance in nociception and its relationship to the potency of morphine-induced analgesia in thermal and chemical tests
- 1 March 1998
- journal article
- Published by Wolters Kluwer Health in Pain
- Vol. 75 (1), 129-140
- https://doi.org/10.1016/s0304-3959(97)00215-7
Abstract
The perceived intensity of a painful stimulus is determined in part by the stimulus intensity and environmental conditions. The purpose of this study was to determine the influence of genetic factors in nociception and its contribution to the potency of morphine to produce antinociception. Eight inbred strains of mice were tested across a range of stimulus intensities in thermal (hot plate) and chemical irritant (acetic acid) nociceptive tests. Stimulus intensities in the thermal test included hot plate temperatures of 51, 53, 55, 57 and 59°C. Stimulus intensities in the chemical irritant test included acetic acid concentrations of 0.1, 0.3 and 0.6%. Linear interpolation of stimulus-effect curves revealed large genotype-dependent differences in the effective temperature resulting in a 10 s latency on the hot-plate (ET 10 ″) and the acetic acid concentration resulting in the same number of writhes as determined by the area under the curve (AUC 50 ). There was no genetic correlation between sensitivity to thermal versus chemical stimuli. Morphine dose response curves were then determined at a fixed stimulus intensity in each test (55°C and 0.6% acetic acid) to determine analgesic ED 50 doses for each inbred strain. A significant effect of genotype on relative sensitivity to morphine-induced analgesia in both the thermal and chemical irritant tests was found, however there was no genetic correlation between the potency of morphine in each test. There was an inverse genetic correlation between sensitivity to thermal and chemical stimuli and morphine ED 50 values in each respective test. In both tests, strains less sensitive to the nociceptive stimuli were more sensitive to the antinociceptive effects of morphine. Confirmation studies in a separate genetic population confirmed the inverse relationship between hot-plate sensitivity and antinoceptive potency. In summary, this study demonstrated (i) a large degree of genetically-determined variability in sensitivity to painful stimuli, (ii) sensitivity to thermal stimuli (hot-plate) is genetically unrelated to sensitivity to chemical (acetic acid) stimuli, (iii) the mechanism by which morphine produces its antinociceptive effects against thermal stimuli is largely genetically independent of the mechanism by which morphine produces its antinociceptive effects against chemical stimuli, and (iv) inherent differences in sensitivity to painful stimuli may be responsible, in part, for individual differences in the potency of morphine's antinociceptive effects.Keywords
This publication has 14 references indexed in Scilit:
- Molecular genetic approaches to nociceptor development and functionTrends in Neurosciences, 1996
- Differential right shifts in the dose-response curve for intrathecal morphine and sufentanil as a function of stimulus intensityPain, 1995
- Localization to chromosome 10 of a locus influencing morphine analgesia in crosses derived from C57BL/ and DBA/2 strainsLife Sciences, 1995
- Migraine and Concomitant Symptoms Among 8167 Adult Twin PairsHeadache: The Journal of Head and Face Pain, 1995
- Genetic influences on brain stimulation-produced analgesia in mice: II. Correlation with brain opiate receptor concentrationBrain Research, 1990
- The correlation of monkey medullary dorsal horn neuronal activity and the perceived intensity of noxious heat stimuliJournal of Neurophysiology, 1989
- Strain differences in the magnitude of swimming-induced analgesia in mice correlate with brain opiate receptor concentrationBrain Research, 1988
- Selective breeding of mice for high and low swim analgesia: differential effect on discrete forms of footshock analgesiaPain, 1987
- Metallic gold precipitation in implanted MgO crystals studied by 197Au conversion electron Mossbauer spectroscopy associated with optical absorption and TEMNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1986
- Comparison of responses of warm and nociceptive C-fiber afferents in monkey with human judgments of thermal painJournal of Neurophysiology, 1978