Haemodynamic effects of propranolol, octreotide and their combination during fasting and post-prandial splanchnic hyperaemia in patients with cirrhosis
- 1 February 2001
- journal article
- clinical trial
- Published by Wolters Kluwer Health in European Journal of Gastroenterology & Hepatology
- Vol. 13 (2), 163-169
- https://doi.org/10.1097/00042737-200102000-00012
Abstract
This double-blind study was designed to evaluate the haemodynamic effect of two drugs, propranolol and octreotide, and their combination in patients with cirrhosis.Fifteen patients with cirrhosis were randomly assigned to two groups receiving either octreotide subcutaneously at 100 microg ('octreotide' group, n = 9) or propranolol orally at 40 mg followed by a subcutaneous dose of octreotide (100 microg) after 1 h ('propranolol + octreotide' group, n = 6); then, after 30 min, a standard meal was administered to both groups. The hepatic vein pressure gradient by hepatic vein catheterization, portal and superior mesenteric artery blood flow velocity, superior mesenteric artery pulsatility index by the echo-Doppler duplex system were recorded at baseline, 1 h after propranolol in the 'propranolol + octreotide' group, and in both groups 30 min after octreotide and 30 min after meal.At fast, propranolol was more active in decreasing portal pressure (from 16 +/- 2.2 to 12.7 +/- 3.8 mmHg, -20%, P < 0.05) as compared to octreotide (from 18.6 +/- 4.8 to 16.6 +/- 4.3 mmHg, -11%, P < 0.05). Conversely, octreotide was more active on the mean blood flow velocity of superior mesenteric artery (from 22.8 +/- 5 to 19 +/- 4.5 cm/ s, -17%; P< 0.05). Octreotide administration in patients receiving beta-blockers showed, also, a trend to increase the mesenteric vascular resistances (pulsatility index from 3.14 +/- 0.69 to 3.68 +/- 1.29, +17%, not significant (NS)) which had not been affected by previous treatment with propranolol. After the meal, a reduction of the expected hyperaemic response occurred in both groups.The combined acute haemodynamic effect of this association suggests the possible combination of these two drugs in critical situations, such as variceal bleeding in patients receiving beta-blockers. The simultaneous use of echo-Doppler and hepatic vein catheterization permitted us a more complete analysis of the acute haemodynamic events.Keywords
This publication has 26 references indexed in Scilit:
- Wedged hepatic venous pressure reflects portal venous pressure during vasoactive drug administration in nonalcoholic cirrhosisDigestive Diseases and Sciences, 1994
- Echo-Doppler evaluation of acute flow changes in portal hypertensive patients: flow velocity as a reliable parameterJournal of Hepatology, 1992
- The effect of non-protein liquid meals on the hepatic venous pressure gradient in patients with cirrhosisJournal of Hepatology, 1990
- Comparison between portal vein pressure and wedged hepatic vein pressure in hepatitis B-related cirrhosisJournal of Hepatology, 1989
- Effect of meal on portal hemodynamics in healthy humans and in patients with chronic liver diseaseHepatology, 1989
- Prophylactic Sclerotherapy before the First Episode of Variceal Hemorrhage in Patients with CirrhosisNew England Journal of Medicine, 1988
- Clinical application of an ultrasonic duplex system in the quantitative measurement of portal blood flowJournal of Clinical Ultrasound, 1986
- The effects of a somatostatin analogue SMS 201-995 on hepatic haemodynamics in the cirrhotic ratBritish Journal of Surgery, 1985
- Increased Portal Venous Resistance Hinders Portal Pressure Reduction During the Administration of β–Adrenergic Blocking Agents in A Portal Hypertensive ModelHepatology, 1985
- Propranolol for Prevention of Recurrent Gastrointestinal Bleeding in Patients with CirrhosisNew England Journal of Medicine, 1981