Comparison of three different ICP-MS instruments in the study of cadmium speciation in rabbit liver metallothionein-1 using reversed-phase HPLC and post-column isotope dilution analysis
- 13 June 2002
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (9), 1024-1029
- https://doi.org/10.1039/b202452g
Abstract
The coupling of reversed-phase high-performance liquid chromatography (RP-HPLC) with inductively coupled plasma mass spectrometry (ICP-MS) using post-column isotope dilution analysis (ID) was applied to the study of cadmium binding to standard rabbit liver metallothionein isoform 1 (MT-1). The analytical performance of three different ICP mass spectrometers, time of flight (TOF), double focussing (DF) and quadrupole (Q), was compared according to their performance for cadmium detection during chromatographic separation. Chromatographic conditions were optimised on a Vydac C8 VHP 259 RP column using a water–methanol gradient. Seven different sub-isoforms were distinguished by using this column coupled to a UV–Vis spectrophotometer, which greatly improved the resolution power exhibited by conventional anion-exchange chromatography. The ICP-DF-MS instrument was seriously affected by the methanol gradient and, thereafter, showed the worst performance in all cases. In contrast, the ICP-TOF-MS was able to resist up to 50% methanol with no serious changes in sensitivity or plasma stability. This instrument exhibited the lowest detection limits. The ICP-Q-MS provided results in between the other two instruments. In all cases, the use of post-column isotope dilution analysis was able to correct for matrix effects and signal drift, allowing for accurate determination of total MT concentration and the actual distribution of Cd-binding sub-isoforms.Keywords
This publication has 27 references indexed in Scilit:
- Metallothionein isoforms separation and cadmium speciation by capillary electrophoresis with ultraviolet and quadrupole-inductively coupled plasma mass spectrometric detectionAnalytica Chimica Acta, 2001
- Speciation of essential elements in human serum using anion-exchange chromatography coupled to post-column isotope dilution analysis with double focusing ICP-MSJournal of Analytical Atomic Spectrometry, 2001
- Speciation of Metallothionein-like Proteins of the Mussel Mytilus edulis at Basal Levels by Chromatographic Separations Coupled to Quadrupole and Double-Focusing Magnetic Sector ICPMSAnalytical Chemistry, 2000
- Detection and identification of rabbit liver metallothionein-2 subisoforms by capillary zone electrophoresis - inductively coupled plasma mass spectrometry and microbore HPLC - electrospray mass spectrometryAnalusis, 2000
- Species-selective Analysis for Metal - Biomacromolecular Complexes using Hyphenated TechniquesPublished by Walter de Gruyter GmbH ,1999
- Detection of artefacts and peak identification in reversed-phase HPLC of metallothioneins by electrospray mass spectrometryTalanta, 1999
- Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: a comparison with quadrupole ICP-MSJournal of Analytical Atomic Spectrometry, 1999
- Effect of Temperature Variation on Metallothionein Sub-Isoform Separation by Reverse Phase High Performance Liquid ChromatographyJournal of Liquid Chromatography & Related Technologies, 1998
- Determination of trace elements in seawater by electrothermal atomic absorption spectrometry with and without a preconcentration stepMicrochimica Acta, 1993
- METALLOTHIONEINAnnual Review of Biochemistry, 1986