Ten years of hemovigilance reports of transfusion‐related acute lung injury in the United Kingdom and the impact of preferential use of male donor plasma
Top Cited Papers
- 13 February 2009
- journal article
- Published by Wiley in Transfusion
- Vol. 49 (3), 440-452
- https://doi.org/10.1111/j.1537-2995.2008.01948.x
Abstract
BACKGROUND AND METHODS: From 1996 through 2006, 195 cases were reported as transfusion-related acute lung injury (TRALI) to the Serious Hazards of Transfusion scheme and from 1999 onward classified by probability, using clinical features and HLA and/or HNA typing. From late 2003, the National Blood Service provided 80 to 90 percent of fresh-frozen plasma (FFP) and plasma for platelet (PLT) pools from male donors. RESULTS: Forty-nine percent of reports were highly likely/probable TRALI, and 51 percent possible/unlikely. Of 96 investigations, donor antibodies recognizing recipient antigens were found in 73 cases (65%), with HLA Class I in 25 of those (40%), HLA Class II antibodies in 38 (62%), and granulocyte antibodies in 12 (17%). A review in 2003 revealed that the TRALI risk/component was 6.9 times higher for FFP and 8.2 times higher for PLTs than for red blood cells, and that in donors of implicated FFP/PLTs, white blood cell antibodies were found 3.6 times more often than by chance (p ≤ 0.0001), with all implicated donors being female. Provision of male plasma was associated with a reduction in TRALI reports from 36 in 2003 to 23 in each of 2004 and 2005 and 10 in 2006. Highly likely/probable cases reduced from 23 in 2003 to 10, 6, and 4 in the 3 subsequent years, with cases implicating FFP or PLTs falling from 16 to 9, 3, and 1 respectively. CONCLUSIONS: The risk of highly likely/probable TRALI due to FFP has fallen from 15.5 per million units issued during 1999 through 2004 to 3.2 per million during 2005 through 2006 (p = 0.0079) and from 14.0 per million to 5.8 per million for PLTs.Keywords
This publication has 43 references indexed in Scilit:
- Overnight storage of whole blood: a comparison of two designs of butane-1,4-diol cooling platesTransfusion, 2007
- Effect of fresh‐frozen plasma transfusion on prothrombin time and bleeding in patients with mild coagulation abnormalitiesTransfusion, 2006
- Transfusion‐related acute lung injury and pulmonary edema in critically ill patients: a retrospective studyTransfusion, 2006
- The quality of fresh‐frozen plasma produced from whole blood stored at 4°C overnightTransfusion, 2005
- Use of B‐natriuretic peptide as a diagnostic marker in the differential diagnosis of transfusion‐associated circulatory overloadTransfusion, 2005
- Transfusion‐Related Acute Lung Injury Associated with Interdonor Incompatibility for the Neutrophil‐Specific Antigen HNA‐1aVox Sanguinis, 2000
- Comprehensive, serologically equivalent DNA typing for HLA‐B by PCR using sequence‐specific primers (PCR‐SSP)Tissue Antigens, 1995
- Prospective Evaluation of the Chemiluminescence Test for the Detection of Granulocyte Antibodies: Comparison with the Granulocyte Immunofluorescence TestVox Sanguinis, 1994
- Transfusion‐related acute lung injury: a neglected, serious complication of hemotherapyTransfusion, 1992
- Diagnostic and pathogenetic considerations in transfusion‐related acute lung injuryTransfusion, 1985